Samsung RB215BSSB Service Manual - Page 56
Ambient Sensor trouble =>applied to Ambient Sensor Temp type
View all Samsung RB215BSSB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Diagnostics 13-2) If there is a trouble with self-diagnosis 1) Ambient Sensor trouble =>(applied to Ambient Sensor Temp type) ERROR INDICATION Start Is Ambient Sensor normal?(At the top right hinge of the refrigerator) YES Is MAIN PCB (CN31) insertion normal? YES Is the connection wire between MAIN PCB connector (CN32)and Temp Sensor normal (at the top right of the door)? YES Is the voltage of Ambient Sensor �~� of MAIN PCB Connector (CN31) normal? Refer to Temp detechion circuit sensor of the circuit explanation. YES Is MICOM Pin#57 input voltage normal? (Identical Voltage �~� of CN31) YES Change PCB NO Change Ambient Sensor NO Connector contact trouble /re-insertion NO Short between connector Sensors (Check wires according to the change of the door opening direction) NO (0.5V>Measured value) Reconfirm electric wire connect section NO (0.5V>Measured value >4.5V) Check soldering fault,short, Lead Touch 56