When COMP does not operate
View all Samsung RB215BSSB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Diagnostics 13-3) When COMP does not operate Pre-Check "Check out the COMP with the Forced Operation selected" 1. If it does not pass 5 min after a desired Temp reached,COMP does not operate. 2. During Defrost,COMP does not operate. 3. With the disconnected F-Sensor or R-Sensor,COMP does not operate because low temperature is detected. Start Is Forced Operation on? YES Is the MICOM #22 output "HIGH"(5V)? YES Is the IC70 #12 "LOW"(0.7V)? YES Is COMP RELAY normal? YES Is the contact of CONNECTOR CN70 contact normal NO Does COMP ASS'Y Function normally? YES Check wire assembly/connection NO Run Forced Operation NO Soldering checkout/ Change MICOM or PCB NO Change or repair IC04/ NO Change PCB YES Check RELAY / Change PCB - Reference • Load terminal Measure method. Insert Connector completely / Check its connection NO Change/repair COMP 59