Samsung SCC-C4355 User Manual - Page 32
Ctrl Type
View all Samsung SCC-C4355 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
setup CTRL TYPE By inputting the wire remote port, you may set up the A, B, C or D mode. Code A Tele Wide Far Near -6V +6V +6V -6V B -6V +6V -6V +6V C +6V -6V +6V -6V D +6V -6V -6V +6V COMMUNICATION You can set the RS-485 communications setting in regard of the camera. 1. Select -. 2. Select each item and set appropriately. PROTOCOL, BAUD RATE, ADDRESS : You can manually set the protocol, baud rate and address. COMMUNICATION RS485 PROTOCOL BAUD RATE ADDRESS SAMSUNG 9600 0 SYSTEM INFO You can check the system information. 1. Select -. 2. The current system information is displayed. SYSTEM INFO TYPE PROTOCOL ADDRESS COMM. TYPE BAUD RATE SERIAL NO. CAMERA VER. 4_ZOM_WDR_N SAMSUNG 0 RS485, HALF 9600 000000000000000 v1.00_00000 32_ setup SC ENGLISH.indd 32 2009-9-22 15:48:3