Sharp PG-M25X PGM25X Operation Manual - Page 117
Resetting the Lamp, Timer
View all Sharp PG-M25X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
4 Loosen the lamp unit. • Remove the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. 5 Insert the new lamp unit. • Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. 6 Attach the lamp unit cover. • Slide the lamp unit cover in the direction of the arrow. Then tighten the user service screw. Securing screw Info • If the lamp unit and lamp cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. 1 Connect the power cord. • Plug the power cord into the AC socket of the projector. 2 Reset the lamp timer. •While pressing simultaneously User service screw AC socket , , and on the projector, press on the projector. • "LAMP 0000H" is displayed, indicating that the lamp timer is reset. POWER button Adjustment buttons ("|) Info • Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode. ENTER button -113 Appendix PG-M25X#E#p107_115.p65 113 02.4.29, 3:26 PM