Sharp PN-655RU PN-655RU Operation Manual - Page 39

<Commands for ID control&gt

Page 39 highlights

ENGLISH Controlling the Monitor with a PC The command examples shown on this page assume the following connection and ID number set up. ID number: 1 ID number: 2 ID number: 3 ID number: 4 PC IDST......A monitor receiving this command sets its own ID number in the parameter field. Example: IDST0001 OK 001 ← The ID number of this monitor is set to 1. TIPS You can automatically assign ID numbers by using the IDST command with the Repeater control (see "Repeater control" on page 39). For example, using the command "IDST001+" automatically sets the ID numbers as shown below. [Example] PC ID number: 1 ID number: 2 ID number: 3 ID number: 4 IDST001+ ← ID setting command with repeater control WAIT OK 001 ← "OK" response from ID number: 1 OK 002 ← "OK" response from ID number: 2 OK 003 ← "OK" response from ID number: 3 OK 004 ← "OK" response from ID number: 4 (End) 37 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

37
E
ENGLISH
<Commands for ID control>
The command examples shown on this page assume the following connection and ID number set up.
ID number: 1
ID number: 2
ID number: 3
ID number: 4
PC
IDST
......
A monitor receiving this command sets its own ID number in the parameter field.
Example:
IDST0001
OK
001 ←
The ID number of this monitor is set to 1.
TIPS
You can automatically assign ID numbers by using the IDST command with the Repeater control (see
“Repeater control” on page 39).
For example, using the command “IDST001+” automatically sets the ID numbers as shown below.
[Example]
ID number: 1
ID number: 2
ID number: 3
ID number: 4
PC
IDST001+ ← ID setting command with repeater control
WAIT
OK
001 ← “OK” response from ID number: 1
OK
002 ← “OK” response from ID number: 2
OK
003 ← “OK” response from ID number: 3
OK
004 ← “OK” response from ID number: 4 (End)
Controlling the Monitor with a PC