Sony EVI D100 Technical Manual - Page 39
Lens control, Others, Pan/Tilter Status Code List, Note: The lower one byte is fixed at 00. - problems
![]() |
UPC - 027242594364
View all Sony EVI D100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Lens control Zoom Position Focus Position Focus Near Limit 0000 to 4000 (Optical Wide end) (Optical Tele end) 4000 to 7000 (Digital Zoom ×1) (Digital Zoom ×4) 1000 (Far) to 8400 (Near) 1000 (Far) to 8400 (Near) Note: The lower one byte is fixed at 00. Others R,B gain Aperture Effect Level (Digital Effect Level) STILL FLASH LUMI. TRAIL 00~FF 00~0F 00~20 00~18 00~20 00~18 Pan/Tilter Status Code List P 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0-0 0 0-0 1 0-1 0 0-1 1 Q --0 0 --0 1 --1 0 0 0-- 0 1-- 1 0-- 1 1-- R 0--- 0--- 0--- 0--- --0 0 --0 1 --1 0 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- 0--- ( - : Optional) S ---1 --1- -1-- 1--- Pan has reached the left endpoint. Pan has reached the right endpoint. Tilt has reached the top endpoint. Tilt has reached the bottom endpoint. Pan is normal. Pan has a position detection error. Pan has a mechanical problem. Tilt is normal. Tilt has a position detection error. Tilt has a mechanical problem. No movement command Pan-Tilt is moving. Pan-Tilt operation is completed. Pan-Tilt operation failed. Not initialized Initializing Initialization completed Initialization failed Command List 39
![](/manual_guide/products/sony-evid100p-technical-manual-82c3e0f/39.png)