Sony STRDG720 Operating Instructions - Page 31

When error codes appear, To rectify the error, Error codes and remedies, Error and warning codes

Page 31 highlights

Getting Started Tips • When Auto Calibration starts: - Stand some distance from the speakers and the listening position to avoid measurement failure. This is because test signals are output from the speakers during measurement. - Avoid making noise to get a more accurate measurement. • The Auto Calibration function will be canceled when you do the following during the measurement process: - Press ?/1 or MUTING. - Press the input buttons or turn the INPUT SELECTOR on the receiver. - Change the volume level. - Connect the headphones. - Press AUTO CAL again. Error and warning codes When error codes appear When an error is detected during Auto Calibration, an error code will appear on the display cyclically after each measurement process as follows: Error code t blank display t (error code t blank display)a) t PUSH t blank display t ENTER a)Appears when there are more than one error code. To rectify the error 1 Record down the error code. 2 Press . 3 Press ?/1 to turn off the receiver. 4 Rectify the error. For details, see "Error codes and remedies" below. 5 Turn on the receiver and perform Auto Calibration again (page 30). Error codes and remedies Error code ERROR 10 ERROR 11 ERROR 12 ERROR 20 ERROR 21 ERROR 22 ERROR 23 Cause and remedy The environment is too noisy. Make sure the environment is quiet during Auto Calibration. The speakers are placed too near the optimizer microphone. Place your speakers further away from the optimizer microphone. None of the speakers are detected. Make sure that the optimizer microphone is connected properly and perform Auto Calibration again. Front speakers are not detected or only one front speaker is detected. Check the front speakers connection. Only one surround speaker is detected. Check the surround speakers connection. The surround back speaker is connected only to the SPEAKERS SURROUND BACK R terminals. When you connect only one surround back speaker, connect it to the SPEAKERS SURROUND BACK L terminals. Surround back speaker is detected but surround speakers are not connected. Be sure to connect the surround speakers. When warning codes appear During Auto Calibration, the warning code provides information on the measurement result. The warning code will appear on the display cyclically as follows: Warning code t blank display t (warning code t blank display)b) t PUSH t blank display t ENTER b)Appears when there are more than one warning code. You can choose to ignore the warning code as the Auto Calibration function will automatically adjust the settings. You can also change the settings manually. continued 31US

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

31
US
Getting Started
Tips
• When Auto Calibration starts:
– Stand some distance from the speakers and the
listening position to avoid measurement failure.
This is because test signals are output from the
speakers during measurement.
– Avoid making noise to get a more accurate
measurement.
• The Auto Calibration function will be canceled
when you do the following during the
measurement process:
– Press
?
/
1
or MUTING.
– Press the input buttons or turn the INPUT
SELECTOR on the receiver.
– Change the volume level.
– Connect the headphones.
– Press AUTO CAL again.
When error codes appear
When an error is detected during Auto
Calibration, an error code will appear on the
display cyclically after each measurement
process as follows:
Error code
t
blank display
t
(error code
t
blank display)
a)
t
PUSH
t
blank display
t
ENTER
a)
Appears when there are more than one error code.
To rectify the error
1
Record down the error code.
2
Press
.
3
Press
?
/
1
to turn off the receiver.
4
Rectify the error.
For details, see “Error codes and remedies”
below.
5
Turn on the receiver and perform Auto
Calibration again (page 30).
Error codes and remedies
When warning codes appear
During Auto Calibration, the warning code
provides information on the measurement
result. The warning code will appear on the
display cyclically as follows:
Warning code
t
blank display
t
(warning
code
t
blank display)
b)
t
PUSH
t
blank
display
t
ENTER
b)
Appears when there are more than one warning
code.
You can choose to ignore the warning code as
the Auto Calibration function will
automatically adjust the settings. You can also
change the settings manually.
Error and warning codes
Error code
Cause and remedy
ERROR 10
The environment is too noisy.
Make sure the environment is quiet
during Auto Calibration.
ERROR 11
The speakers are placed too near
the optimizer microphone. Place
your speakers further away from
the optimizer microphone.
ERROR 12
None of the speakers are detected.
Make sure that the optimizer
microphone is connected properly
and perform Auto Calibration
again.
ERROR 20
Front speakers are not detected or
only one front speaker is detected.
Check the front speakers
connection.
ERROR 21
Only one surround speaker is
detected. Check the surround
speakers connection.
ERROR 22
The surround back speaker is
connected only to the SPEAKERS
SURROUND BACK R terminals.
When you connect only one
surround back speaker, connect it to
the SPEAKERS SURROUND
BACK L terminals.
ERROR 23
Surround back speaker is detected
but surround speakers are not
connected. Be sure to connect the
surround speakers.
continued