ViewSonic E70FSB-2 Service Manual - Page 16
Adjusting Procedure
UPC - 766907870558
View all ViewSonic E70FSB-2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
5. Adjusting Procedure 5-1 ADJUSTMENT CONDITIONS AND PRECAUTIONS 1. Approximately 30 minutes should be allowed for warm up before proceeding. 2. Adjustments should be undertaken only on those necessary elements since most of them have been carefully preset at the factory. 5-2 MAIN ADJUSTMENTS NO. FUNCTION LOCATION DESIGNATION 1. 14V ADJ 2. B + ADJ 3. SCREEN ADJ 4. FOCUS ADJ 5. ABL ADJ 6. FUNCTION ADJ 5-3 ADJUSTMENT METHOD -MENU -UP -DOWN -EXIT -RECALL PCB - MAIN PCB - MAIN FLY BACK TRANS FLY BACK TRANS PCB - MAIN PCB - MAIN PCB - MAIN PCB - MAIN PCB - MAIN PCB - MAIN VR903 VR902 T402 SCREEN VR T402 FOCUS VR1&VR2 AB in factory OSD SW104 SW103 (SW103) 1. 14V, B + & HV voltage adjustment: A. Chroma-2000 Signal generator or PC equivalent set mode 1, VGA 640X480 pattern 1.0. B. Connect a DC Volt meter between TP901 and ground, then adjust VR903to be 14VDC. C. Connect a DC Volt meter between TP902 and ground, then adjust VR902 to be 64 VDC. 2. Factory preset Timings Adjustment: A. Press Key to show OSD window press Up or Down Key to switch the functional controls. B. Press the Up Key to select the "ZOOM" function, then press the MENU Key. While do not release the MENU Key until the OSD window changed to the Factory preset window. C. The Factory preset window contains the following functional controls. Select one of the control. Then press the Up/Down Key to adjust its value for the optimum picture. ViewSonic Corporation 13 Confidential - Do Not Copy E70f-5_E70fB-5_E70fSB-5