<Interface>, <RS232 command table>, RS-232 protocol, Baud Rate, bps default, Data Length
View all ViewSonic PJD7822HDL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Baud Rate Data Length Parity Check Stop Bit Flow Control RS-232 protocol 115200 bps (default) 8 bit None 1 bit None Function Status Action cmd Power Write Read Turn on Turn off Power status (on/off) 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x00 0x00 0x5D 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x01 0x00 0x5E 0x07 0x14 0x00 0x05 0x00 0x34 0x00 0x00 0x11 0x00 0x5E Reset all settings Execute 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x02 0x00 0x5F Reset Color Settings Execute 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x2A 0x00 0x87 Splash Screen Black 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0A 0x00 0x67 Splash Screen Blue 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0A 0x01 0x68 Splash Screen Write Splash Screen ViewSonic Splash Screen Screen Capture 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0A 0x02 0x69 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0A 0x03 0x6A Splash Screen Off 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0A 0x04 0x6B Read Splash Screen status 0x07 0x14 0x00 0x05 0x00 0x34 0x00 0x00 0x11 0x0A 0x68 High Altitude Mode Write Read High Altitude Mode Off High Altitude Mode On High Altitude Mode status 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0C 0x00 0x69 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x0C 0x01 0x6A 0x07 0x14 0x00 0x05 0x00 0x34 0x00 0x00 0x11 0x0C 0x6A Lamp Mode Write Lamp Mode Normal Lamp Mode Economic 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x10 0x00 0x6D 0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x10 0x01 0x6E Read Lamp Mode status 0x07 0x14 0x00 0x05 0x00 0x34 0x00 0x00 0x11 0x10 0x6E 66