Viking VBCV42381 Installation Instructions - Page 8

Wall Hood Dimensions, Indoor/outdoor Vwh Models, Exterior Ventilator Dimensions, Vev900, Vev1200,

Page 8 highlights

EXTERIOR VENTILATOR DIMENSIONS VEV900 10" Dia. 281/4" (71.8 cm) 151/2" (39.4 cm) 203/4" (52.7 cm) 241/2" (62.2 cm) VEV1200 VEV1500 Opening for wiring A 291/2" (74.9 cm) 101/8" 25.7 cm 10" (25.4 cm) Dia. 221/8" (56.2 cm) 14" (35.6 cm) 243/4" (62.9 cm) 43/4" (12.1 cm) Flashing B VEV1200 VEV1500 Flashing A B 18" 22" (45.7 cm) (55.9 cm) 21" 25" (53.3 cm) (55.9 cm) 14 WALL HOOD DIMENSIONS (Indoor/Outdoor VWH Models) 1 1/2" (3.81 cm) 12" (30.5 cm) 1" (2.54 cm) 18" (45.7 cm) 6" (15.2 cm) 24" (61.0 cm) or 27" (68.6 cm) FOR 900, 1200 or 1500 CFM EXTERIOR VENTILATOR INSTALLATION 1 1/2" (3.81 cm) Transition VIV1200 Only 9" (22.9 cm) 7/8" (2.22 cm) 18" (45.7 cm) 24" (61.0 cm) or 27" (68.6 cm) FOR 300, 600 or 1200 CFM INTERIOR VENTILATOR INSTALLATION 5 15/16" (15.1cm) 1 1/16" (2.7 cm) 9 3/4" (24.8 cm) B 8 1/4" (20.9 cm) 6 7/16" (16.4cm) 120 V 3" (7.62 cm) 2 1/2"(6.35 cm) Cutout for 10" (25.4 cm) duct. B 18 3/4" (47.6 cm) 93/8" (23.8 cm) 5/8" (1.6 cm) 4 5/8" (11.7 cm) 9 5/8" (24.4 cm) 7" (17.8 cm) dia. Duct Location 9 1/8" (23.2 cm) A FOR 900 or 1200 CFM EXTERIOR VENTILATOR INSTALLATION 24", 30", 36", 42" W. Models A FOR 300 or 600 CFM INTERIOR VENTILATOR INSTALLATION 24", 30", 36", 42" W. Models *Note: "Dotted Line represents cutout. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

15
WALL HOOD DIMENSIONS
(Indoor/Outdoor VWH Models)
FOR 900, 1200 or 1500 CFM EXTERIOR
VENTILATOR INSTALLATION
18”
(45.7 cm)
6” (15.2 cm)
24” (61.0 cm)
or 27” (68.6 cm)
1 1/2”
(3.81 cm)
1” (2.54 cm)
8 1/4”
(20.9 cm)
2 1/2”(6.35 cm)
5 15/16”
(
15.1cm
)
6 7/16”
(16.4cm)
3” (7.62 cm)
1 1/16”
(2.7 cm)
A
A
18 3/4” (47.6 cm)
9
3
/8”
(23.8 cm)
9 1/8”
(23.2 cm)
9 5/8”
(24.4 cm)
FOR 900 or 1200 CFM EXTERIOR
VENTILATOR INSTALLATION
24”, 30”, 36”, 42” W. Models
FOR 300 or 600 CFM INTERIOR
VENTILATOR INSTALLATION
24”, 30”, 36”, 42” W. Models
4 5/8”
(11.7 cm)
B
5/8” (1.6 cm)
B
12”
(30.5 cm)
Cutout for 10”
(25.4 cm) duct.
7” (17.8 cm) dia.
Duct Location
*Note: “Dotted Line” (
........
) represents cutout.
120
V
FOR 300, 600 or 1200 CFM INTERIOR
VENTILATOR INSTALLATION
24” (61.0 cm)
or 27” (68.6 cm)
18”
(45.7 cm)
1 1/2”
(3.81 cm)
7/8”
(2.22 cm)
9” (22.9 cm)
Transition
VIV1200 Only
9 3/4” (24.8 cm)
14
EXTERIOR VENTILATOR DIMENSIONS
10” Dia.
20
3
/4
” (52.7 cm)
24
1
/2
(62.2 cm)
4
3
/4
(12.1 cm)
14”
(35.6 cm)
24
3
/4
(62.9 cm)
15
1
/2
(39.4 cm)
28
1
/4
(71.8 cm)
VEV900
VEV1200
VEV1500
22
1
/
8
(56.2 cm)
B
10
1
/
8
25.7 cm
A
29
1
/
2
(74.9 cm)
10” (25.4 cm) Dia.
Opening for wiring
Flashing
Flashing
A
B
VEV1200
18”
22”
(45.7 cm)
(55.9 cm)
VEV1500
21”
25”
(53.3 cm)
(55.9 cm)