Viking VWH4878TSS Installation Instructions

Viking VWH4878TSS Manual

Viking VWH4878TSS manual content summary:

  • Viking VWH4878TSS | Installation Instructions - Page 1
    Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20470G EN UL C UL (033111) Professional Hoods
  • Viking VWH4878TSS | Installation Instructions - Page 2
    for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are
  • Viking VWH4878TSS | Installation Instructions - Page 3
    SHOCK, OR INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted. 4 Dimensions & Specifications (VWH 10"H. Wall Hoods w/Standard Ventilator 24", 30", & 36") (7.63"cm
  • Viking VWH4878TSS | Installation Instructions - Page 4
    .46"cm) ((6611356020""t..mmo40 accinmmx..)) 22((766418""..mt06moaccimmxn..))* * NOTE: When installing with a 24" high-shelf, the 27" (68.6 cm) max. dimensions must be used. 6 Interior Ventilator Dimensions (VWH 10"H. Wall Hoods w/Standard Ventilator) Top View 24"W. 30"W. 36"W. 24"W. 30"W. 36
  • Viking VWH4878TSS | Installation Instructions - Page 5
    cover height 12" (30.5 cm) Number of lights 2 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 4 4 Heat lamps 1 1 1 1 2 2 2 2 Interior kit must be purchased for installation with all 18"H. hoods. 8 Clearance Dimensions (VWH 18"H. Wall Hoods) (913.46"cm) ((7611268672
  • Viking VWH4878TSS | Installation Instructions - Page 6
    91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 53-7/8" (136.8 cm) 59-7/8" (152.1 cm) 65-7/8" (167.3 cm) B 900 or 1200 CFM Exterior Ventilator Installation for all Wall Hoods Top View 5-15/16" (15.1 cm) A 8-3/16" (20.7 cm) 24"W. 30"W. 36"W. 42"W. 48"W. 54"W. 60"W. 66"W. A 11-15/16" (30.3 cm) 14
  • Viking VWH4878TSS | Installation Instructions - Page 7
    "H. T-Series Wall Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Interior Note: T-Series Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible. The bottom of the hood should
  • Viking VWH4878TSS | Installation Instructions - Page 8
    (30.5 cm) to 24" (61.0 cm) 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 3 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits kit must be purchased for installation with all 18"H. hoods. 14 Clearance Dimensions (VCWH Chimney Wall Hoods) (913.46"cm)
  • Viking VWH4878TSS | Installation Instructions - Page 9
    18" (45.7 cm) 18" (45.7 cm) 24" (61.0 cm) 24" (61.0 cm) 1200 CFM Interior Ventilator Installation for 48", 54", 60", & 66" models 16 Exterior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. A 14
  • Viking VWH4878TSS | Installation Instructions - Page 10
    filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps VIH Island Hoods for installation with all 18"H. hoods. 18 Clearance Dimensions (VIH Island Hoods) (
  • Viking VWH4878TSS | Installation Instructions - Page 11
    cm) dia. duct location 8-1/4" (20.9 cm) 6-7/16" (16.4 cm) 120 V 3" (7.62 cm) 2-1/2" (6.35 cm) B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Island Hoods Top View 36"W. 42"W. 54"W. 66"W. 36"W. 42"W. 54"W. 66"W. A 17-15/16" (45.6 cm) 20-15/16" (18.2 cm) 26-15/16" (68
  • Viking VWH4878TSS | Installation Instructions - Page 12
    separately. VCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kit must be purchased for installation with all 18"H. hoods. 22 Clearance Dimensions (VCIH Chimney Island Hoods) (913.46"cm) ((
  • Viking VWH4878TSS | Installation Instructions - Page 13
    ) 1-1/8" (2.9 cm) 120 V power supply 1-1/8" (2.9 cm) 10" (25.4 cm) dia. duct location B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods Top View 54"W. 66"W. 54"W. 66"W. 54"W. 66"W. C 1-1/8" (2.9 cm) A 26-15/16" (68.4 cm) A 32-15/16" (83.7 cm) B 53
  • Viking VWH4878TSS | Installation Instructions - Page 14
    54" 60" 66" Number of lights 2 2 2 3 3 4 4 Number of filters 2 2 2 3 3 4 4 Heat lamps 1 1 1 2 2 2 2 installation with all 18"H. hoods. 26 Installing Hood Canopy (Custom Hood Canopy Cutouts) Custom Hood Canopy A B 1) Position ventilator system inside of the custom hood
  • Viking VWH4878TSS | Installation Instructions - Page 15
    Custom Hood) (913.46"cm) ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). 28 Built-In Wall Custom Ventilator System Dimensions (VBCV Models) 1-1/2" (3.81 cm) 1" (2.54 cm) 5/8" (1.6 cm) 21-7/8" (55.8 cm) For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
  • Viking VWH4878TSS | Installation Instructions - Page 16
    CFM Exterior or In-Line Ventilator Installation 48", 54", 60", 66" W. Models 5-1/2" (14.0 cm) 10" Hood Depth) 27-9/16" (70.0 cm) 27-9/16" (70.0 cm) 27-9/16" (70.0 cm) 27-9/16" (70.0 cm) VICV Island Custom Ventilator System Description 36" 42" 54" Number of lights 4 4 6 Number of filters
  • Viking VWH4878TSS | Installation Instructions - Page 17
    Installing Hood Canopy (Custom Hood Canopy Cutouts) Custom Hood Canopy A B 1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right. 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided. Built
  • Viking VWH4878TSS | Installation Instructions - Page 18
    .2 cm) 120 V 3" (7.6 cm) 10" (25.4 cm) dia. duct location 2-1/2" (6.4 cm) 5/8" (1.6 cm) A 900 or 1200 CFM External or In-Line Power 36", 42" W. Models 36" W. 42" W. A 34-1/4" (87.0 cm) 40-1/4" (102.2 cm) 6" (15.2 cm) 5/8" (1.6 cm) 27-7/16" (69.7 cm) (including screw heads) 28-7/16" (72.2 cm
  • Viking VWH4878TSS | Installation Instructions - Page 19
    and geographic location. Electrical Supply Run 120 VAC electrical wiring from service panel to installation location. See Specifications pages for the maximum amp requirements. 36 Installation (VWH 10"H. Wall Hoods w/Standard Ventilator) 1 2 4 5/16" nut driver Check damper for unrestricted
  • Viking VWH4878TSS | Installation Instructions - Page 20
    filter rear up, then slide back over rear lip. Duct Cover Option (VWH 10"H. Wall Hoods w/Standard Ventilator) 1 2 2 Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH 10"H. Wall Hoods
  • Viking VWH4878TSS | Installation Instructions - Page 21
    service panel. 6 7 1 5/16" nut driver 2 Flip hood over. Insert 6" of electrical wiring through the top of vent hood and secure. Refer to local codes. CAUTION: Secure vent hood wiring must be properly installed for wiring to be filters. 2 3 Slide filter front over front lip. Push filter
  • Viking VWH4878TSS | Installation Instructions - Page 22
    hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. To install ventillation kit refer to ventillation kit installation instructions filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option (VWH 18"H. Wall Hoods)
  • Viking VWH4878TSS | Installation Instructions - Page 23
    from inside canopy using the sheet metal screws provided. 44 Installation (VIH/VCIH Island Hoods) 1 2 Check framing where cutout will be. NOTE: . (Option A - VCIH only) Using threaded rod for additional support. (Option B) Attaching hood directly to soffit or duct cover. (Skip to step 3) Cut
  • Viking VWH4878TSS | Installation Instructions - Page 24
    does not stick down past the cover. To install ventillation kit refer to ventillation kit installation instructions. Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. 5 1 6 1 2 3 Slide filter front over front lip. Push filter rear up, then slide back over rear lip
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

F20470G EN
(033111)
U
L
C
U
L
Viking Installation Guide
Professional Hoods
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com