Viking VWH4878TSS Installation Instructions - Page 10

VIH Island Hoods

Page 10 highlights

Dimensions & Specifications (VIH Island Hoods 36", 42", 54", & 66") (15.62"cm) A (Hood width) 36"W. 35-7/8" (91.1 cm) 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) 66"W. 65-7/8" (167.3 cm) (301.52"cm) (451.78"cm) A (763.20"cm) NOTE: Optional duct cover sold separately. Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps VIH Island Hoods 36" 42" 54" 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 53-7/8" (136.8 cm) 12" (30.5 cm) 12" (30.5 cm) 4 4 6 4 4 6 VINV600/1200* DEV900/1200* N/A VINV600/1200* VINV1200* DEV900/1200*/1500** DEV1200*/1500** DIL900/1200 7" (17.8 cm)/ 10" (25.4 cm) DIL900/1200 7" (17.8 cm)/ 10" (25.4 cm) DIL1200 10" (25.4 cm) 4.6/7.7 10" (25.4 cm) 4.6/7.7 8.5 7.4/4.7 7.4/4.7/5.5 5.5/6.2 4.7/6.5 4.7/6.5 7.3 66" 65-7/8" (167.3 cm) 8 8 VINV1200* DEV1200*/1500** DIL1200 10" (25.4 cm) 9.3 6.3/7.1 8.1 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 18 Clearance Dimensions (VIH Island Hoods) (913.46"cm) ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

19
Dimensions & Specifications
18
30”
(76.2 cm)
A
18”
(45.7 cm)
6”
(15.2 cm)
A (Hood width)
36”W.
35-7/8” (91.1 cm)
42”W.
41-7/8” (106.4 cm)
54”W.
53-7/8” (136.8 cm)
66”W.
65-7/8” (167.3 cm)
12”
(30.5 cm)
(VIH Island Hoods 36”, 42”, 54”, & 66”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
36”
(91.4 cm)
Clearance Dimensions
(VIH Island Hoods)
NOTE:
Optional duct cover sold separately.
VIH Island Hoods
Description
36”
42”
54”
66”
Duct cover width
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
4
4
6
8
Number of filters
4
4
6
8
Heat lamps
N/A
Interior ventilator kits
VINV600/1200*
VINV600/1200*
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/1200*
DEV900/1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL1200
DIL1200
Interior duct size
7” (17.8 cm)/
10” (25.4 cm)
7” (17.8 cm)/
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.6/7.7
4.6/7.7
8.5
9.3
Exterior—Maximum amps
7.4/4.7
7.4/4.7/5.5
5.5/6.2
6.3/7.1
In-Line—Maximum amps
4.7/6.5
4.7/6.5
7.3
8.1