Viking VWH4878TSS Installation Instructions - Page 2

Table of Contents, IMPORTANT - outdoor series

Page 2 highlights

Table of Contents Warnings & Important Information 3-4 VWH 10"H. Wall Hoods w/Standard Ventilator 24", 30", & 36" Dimensions & Specifications 5 Clearance Dimensions 6 Interior Ventilator Dimensions 7 VWH 18"H. 24"/27" Deep Wall Hoods 24", 30", 36", 42", 48", 54", 60", & 66" Dimensions & Specifications 8 Clearance Dimensions 9 Interior Ventilator Dimensions 10 Exterior Ventilator Dimensions 11 VWH 18"H. T-Series Wall Hoods 36", 48", & 60" Dimensions & Specifications 12 Clearance Dimensions 13 VCWH Chimney Wall Hoods 30", 36", 42", 48", 54", 60", & 66" Dimensions & Specifications 14 Clearance Dimensions 15 Interior Ventilator Dimensions 16 Exterior Ventilator Dimensions 17 VIH Island Hoods 36", 42", 54", & 66" Dimensions & Specifications 18 Clearance Dimensions 19 Interior Ventilator Dimensions 20 Exterior Ventilator Dimensions 21 VCIH Chimney Island Hoods 36", 42", 54", & 66" Dimensions & Specifications 22 Clearance Dimensions 23 Interior Ventilator Dimensions 24 Exterior Ventilator Dimensions 25 VBCV Wall Custom Ventilator System Dimensions & Specifications 26 Installing Hood Canopy 27 Clearance Dimensions 28 VBCV Ventilator Dimensions 29 VICV Island Custom Ventilator System Dimensions & Specifications 31 Installing Hood Canopy 32 Clearance Dimensions 33 VICV Ventilator Dimensions 34 Planning Information 36 Installation Procedures Installation (VWH 10"H. Wall Hoods w/Standard Ventilator 37 Duct Cover Option (VWH 10"H. Wall Hoods w/Standard Ventilator 39 Installation (VWH 10"H. Wall Hoods w/Recirculating Kit 39 Installation (VWH 18"H. Wall & VCWH Chimney Wall Hoods 42 Duct Cover Option (VWH 18"H. Wall Hoods 43 Duct Cover Option (VCWH Chimney Wall Hoods 44 Installation (VIH/VCIH Island Hoods 45 Service & Registration 47 2 IMPORTANT-Please Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first. IMPORTANT - PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. • Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition. • Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible. • The installer should leave these instructions with the consumer who should retain for local inspector's use and for future reference. • Check with a qualified and trained installer or local codes for makeup air requirement, if any. This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty. Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty. READ AND SAVE THESE INSTRUCTIONS WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 4. Ducted fans must always be vented to the outdoors. 5. WARNING!: To reduce risk of fire, use only metal ductwork 6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages. 7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers - DEV900/DEV1200, VEV900/VEV1200, OR DEV1500, VEV1500 or integral blowers manufactured by Viking, model numbers - DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. NOTE - Please refer inside for specific canopy/blower combinations. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Table of Contents
3
IMPORTANT–
Please Read and Follow!
NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels, warnings, or
plates from the product. This may void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire in
accordance with the National Electrical Code,
ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed
in a covered non-enclosed area and should be protected
from the elements as much as possible.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and
for future reference.
• Check with a qualified and trained installer or local codes
for makeup air requirement, if any.
This hood is for residential installation only and is not
designed for installation over a commercial product. Make
sure power is off at the main circuit breaker or fuse box
before making connections. To avoid risk of fire, electric
shock, or injury to persons, turn off the electricity to the
hood from the power supply before servicing or cleaning.
Viking hoods are equipped with variable speed control
blowers. These units will not function with a single speed
ventilator. All Viking Range ventilator kits are designed
specifically for use with Viking Range hoods. Use of any
non-Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed
controls for blowers. These units will not function with a
single speed ventilator. All Viking ventilator kits are
designed specifically for use with Viking hoods. Use of any
non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
2. Sufficient air is needed for proper combustion
and exhausting of gases through the flute
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
3. When cutting of drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
4. Ducted fans must always be vented to the outdoors.
5.
WARNING!:
To reduce risk of fire, use only
metal ductwork
6.
CAUTION!:
To reduce risk of fire and to
properly exhaust air, be sure to duct air outside.
Do not vent exhaust air into spaces within walls
or ceilings, or into attics, crawl spaces, or
garages.
7.
CAUTION!:
To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only with
remote blower models manufactured by Viking,
model numbers – DEV900/DEV1200,
VEV900/VEV1200, OR DEV1500, VEV1500 or
integral blowers manufactured by Viking, model
numbers – DIV300, DIV440, DIV600, DIV800,
DIV1200, VIV300, VIV600, or VIV1200. NOTE –
Please refer inside for specific canopy/blower
combinations.
WARNING
WARNING
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
2
Warnings & Important Information
________________________________________________________
3-
4
VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”
Dimensions & Specifications _____________________________________________________ 5
Clearance Dimensions ___________________________________________________________ 6
Interior Ventilator Dimensions ____________________________________________________ 7
VWH 18”H. 24”/27” Deep Wall Hoods 24”, 30”, 36”, 42”, 48”, 54”, 60”, & 66”
Dimensions & Specifications ______________________________________________________ 8
Clearance Dimensions _____________________________________________________________ 9
Interior Ventilator Dimensions _____________________________________________________ 10
Exterior Ventilator Dimensions ___________________________________________________ 11
VWH 18”H. T-Series Wall Hoods 36”, 48”, & 60”
Dimensions & Specifications _____________________________________________________ 12
Clearance Dimensions __________________________________________________________ 13
VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”
Dimensions & Specifications _____________________________________________________ 14
Clearance Dimensions __________________________________________________________ 15
Interior Ventilator Dimensions
___________________________________________________ 16
Exterior Ventilator Dimensions ___________________________________________________ 17
VIH Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _____________________________________________________ 18
Clearance Dimensions ___________________________________________________________ 19
Interior Ventilator Dimensions
___________________________________________________ 20
Exterior Ventilator Dimensions ___________________________________________________ 21
VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _____________________________________________________ 22
Clearance Dimensions ___________________________________________________________ 23
Interior Ventilator Dimensions
___________________________________________________ 24
Exterior Ventilator Dimensions ___________________________________________________ 25
VBCV Wall Custom Ventilator System
Dimensions & Specifications _____________________________________________________ 26
Installing Hood Canopy _________________________________________________________ 27
Clearance Dimensions ___________________________________________________________ 28
VBCV Ventilator Dimensions _____________________________________________________ 29
VICV Island Custom Ventilator System
Dimensions & Specifications _____________________________________________________ 31
Installing Hood Canopy _________________________________________________________ 32
Clearance Dimensions ___________________________________________________________ 33
VICV Ventilator Dimensions ______________________________________________________ 34
Planning Information________________________________________________________________ 36
Installation Procedures
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) __________________________37
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)___________________ 39
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit)_____________________________ 39
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) ________________________ 42
Duct Cover Option (VWH 18”H. Wall Hoods)_______________________________________ 43
Duct Cover Option (VCWH Chimney Wall Hoods) __________________________________ 44
Installation (VIH/VCIH Island Hoods) ______________________________________________ 45
Service & Registration_______________________________________________________________ 47