Viking VWH4878TSS Installation Instructions - Page 8

VCWH Chimney Wall Hoods

Page 8 highlights

Dimensions & Specifications (VCWH Chimney Wall Hoods 30", 36", 42", 48", 54", 60", & 66") A A (Duct width) 30"W. 12" (30.5 cm) 36"W. 12" (30.5 cm) 42"W. 12" (30.5 cm) 48"W. 18" (45.7 cm) 54"W. 18" (45.7 cm) 60"W. 24" (61.0 cm) 66"W. 24" (61.0 cm) B (Hood width) 30"W. 29-7/8" (76.2 cm) (15.62"cm) 36"W. 35-7/8" (91.1 cm) 42"W. 41-7/8" (106.4 cm) 48"W. 47-7/8" (121.6 cm) 54"W. 53-7/8" (136.8 cm) 60"W. 59-7/8" (152.1 cm) B 66"W. 65-7/8" (167.3 cm) (612.04"cm) ((360112..t5024o""ccmm)) (451.78"cm) NOTE: Optional duct cover sold separately. VCWH Chimney Wall Hoods Description 30" 36" 42" 48" 54" 60" 66" Duct cover width 12" (30.5 cm) 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 18" (45.7 cm) 24" (61.0 cm) 24" (61.0 cm) Duct cover depth 12" (30.5 cm) Duct cover height Number of lights 12" (30.5 cm) to 24" (61.0 cm) 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 3 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits 1 1 VINV300/600 VINV300/600 DEV900/ 1200* DIL900/1200 DEV900/ 1200* DIL900/1200 1 VINV600 DEV900/ 1200* DIL900/1200 2 VINV1200* DEV1200*/ 1500** DIL1200 2 VINV1200* DEV1200*/ 1500** DIL1200 2 VINV1200* DEV1200*/ 1500** DIL1200 2 VINV1200* DEV1200*/ 1500** DIL1200 Interior duct size 7" (17.8 cm) 7" (17.8 cm) 7" (17.8 cm) 10" (25.4 cm) 10" (25.4 cm) 10" (25.4 cm) 10" (25.4 cm) Exterior duct size Interior-Maximum amps Exterior-Maximum amps 4.9/5.9 8.7/6.0 4.9/5.9 8.7/6.0 5.9 8.7/6.0 10" (25.4 cm) 11.5 8.5/9.2 11.5 8.5/9.2 11.9 8.5/9.2 11.9 8.5/9.2 In-Line-Maximum amps 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 14 Clearance Dimensions (VCWH Chimney Wall Hoods) (913.46"cm) ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

15
Dimensions & Specifications
14
24”
(61.0 cm)
B
A
18”
(45.7 cm)
12”
(30.5 cm)
to
24”
(61.0 cm)
6”
(15.2 cm)
A (Duct width)
30”W.
12“ (30.5 cm)
36”W.
12“ (30.5 cm)
42”W.
12“ (30.5 cm)
48“W.
18“ (45.7 cm)
54”W.
18“ (45.7 cm)
60”W.
24“ (61.0 cm)
66”W.
24“ (61.0 cm)
B (Hood width)
30”W.
29-7/8“ (76.2 cm)
36”W.
35-7/8” (91.1 cm)
42”W.
41-7/8” (106.4 cm)
48“W.
47-7/8” (121.6 cm)
54”W.
53-7/8” (136.8 cm)
60”W.
59-7/8” (152.1 cm)
66”W.
65-7/8” (167.3 cm)
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE:
Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
36”
(91.4 cm)
Clearance Dimensions
(VCWH Chimney Wall Hoods)
NOTE:
Optional duct cover sold separately.
VCWH Chimney Wall Hoods
Description
30”
36”
42”
48”
54”
60”
66”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
18” (45.7 cm)
24” (61.0 cm)
24” (61.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) to 24” (61.0 cm)
Number of lights
2
2
2
3
3
4
4
Number of filters
2
2
2
2
3
3
3
Heat lamps
1
1
1
2
2
2
2
Interior ventilator kits
VINV300/600
VINV300/600
VINV600
VINV1200*
VINV1200*
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL900/1200
DIL1200
DIL1200
DIL1200
DIL1200
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.9/5.9
4.9/5.9
5.9
11.5
11.5
11.9
11.9
Exterior—Maximum amps
8.7/6.0
8.7/6.0
8.7/6.0
8.5/9.2
8.5/9.2
8.5/9.2
8.5/9.2
In-Line—Maximum amps
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7
10.7