Weber 3100 NG Owner Manual - Page 14

Step 11, Step 12

Page 14 highlights

Step 10 Install igniter Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system. The igniter lock nut is on the igniter. Insert the top of the igniter up through the large part of the keyhole in the frame brace. Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Tighten the igniter lock nut. Figure 11. Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers. Step 11 Check that all burner valves are off You will need: one burner control knob. (Valves are shipped in the OFF position, but you should check to be sure.) Put the knob on each valve. Check by pushing down and turning clockwise. If they do not turn they are off, proceed to the next step. Figure 12. (a) Figure 12 Figure 11 Frame brace (b) Step 12 Connect flexible hose to manifold You will need: the 12 foot natural gas supply hose and a 3/4 inch wrench. Thread fitting end of hose onto manifold. Figure 13 (a). Tighten with wrench. (a) Keyhole in frame brace Igniter lock nut (c) Frame brace Small part of keyhole in frame brace Figure 13 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

14
Step 10
Install igniter
Note - The igniter wires are already attached to the Gas
Catcher Ignition Chamber and the igniter. This was done to
factory test the ignition system.
The igniter lock nut is on the igniter.
Insert the top of the igniter up through the large part of the
keyhole in the frame brace. Loosen the igniter lock nut and
slide the igniter into the small part of the keyhole. Tighten
the igniter lock nut. Figure 11.
Note - If the igniter works loose, carefully tighten the igniter
lock nut with an adjustable wrench or pliers.
Figure 11
Igniter lock nut
Keyhole in
frame brace
Step 11
Check that all burner valves are off
You will need: one burner control knob.
(Valves are shipped in the OFF position, but you should
check to be sure.) Put the knob on each valve. Check by
pushing down and turning clockwise. If they do not turn
they are off, proceed to the next step. Figure 12.
Figure 12
Step 12
Connect flexible hose to manifold
You will need: the 12 foot natural gas supply hose and a
3/4 inch wrench.
Thread fitting end of hose onto manifold. Figure 13 (a).
Tighten with wrench.
Figure 13
(a)
Small part of
keyhole in
frame brace
Frame brace
Frame brace
(a)
(b)