Weber 3100 NG Owner Manual - Page 30

Crossover Ignition System Operations

Page 30 highlights

i) Reinstall the Spider Stopper Guards. Slightly rotate the Spider Stopper Guards so that the seams are in line with the Venturi fins. There should be no gaps in the seams or in the fit around the burners and valves. Figure 16. Crossover Ignition System Operations If the Crossover Ignition System fails to ignite the Front burner, light the Front burner with a match. If the Front burner lights with a match, then check the Crossover Ignition System. s Check that both the white and black ignition wires are attached properly. Figure 17. Venturi fin Check fit around valve Check fit around burner Figure 16 ƽCAUTION: If the Spider Stopper Guards do not fit tightly, contact Weber-Stephen Customer Service. ƽCAUTION: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the barbecue. (See Step "Check for gas leaks".) White wire Black wire Figure 17 s Check that the Crossover Ignition button pushes the igniter (button) down, and returns to the up position. s Check to see if the igniter is loose in the frame. Tighten if necessary; see Step "Install igniter" for correct procedure. If the Crossover Ignition System still fails to light, contact Weber-Stephen Customer Service. 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

30
30
Crossover Ignition System Operations
If the Crossover Ignition System fails to ignite the Front
burner, light the Front burner with a match. If the Front
burner lights with a match, then check the Crossover
Ignition System.
Check that both the white and black ignition wires are
attached properly. Figure 17.
Figure 17
White wire
Black wire
i)
Reinstall the Spider Stopper Guards. Slightly rotate
the Spider Stopper Guards so that the seams are in
line with the Venturi fins. There should be no gaps in
the seams or in the fit around the burners and valves.
Figure 16.
Venturi fin
Check fit around burner
Figure 16
Check fit around
valve
m
CAUTION: If the Spider Stopper Guards do not fit
tightly, contact Weber-Stephen Customer Service.
m
CAUTION: After reinstalling the gas lines, they should
be leak checked with a soap and water solution before
using the barbecue. (See Step "Check for gas leaks".)
Check that the Crossover Ignition button pushes the
igniter (button) down, and returns to the up position.
Check to see if the igniter is loose in the frame.
Tighten if necessary; see Step “Install igniter” for
correct procedure.
If the Crossover Ignition System still fails to light, contact
Weber-Stephen Customer Service.