Three-wire connection... Three-wire receptacle POWER SUPPLY CORD spade terminals with upturned ends ring terminals This blade connected to this conductor. NEUTRAL 3/4" U.L.-listed NEUTRAL strain relief (white or center) Where local codes permit connecting cabinet-ground conductor to neutral wire: 4. Loosen or remove center terminal block screw. 5. Connect the neutral wire (white or center) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw. 6. Connect the other wires to outer terminal block screws. Tighten screws. 7. Tighten strain relief screws. Three-wire power supply cord must have three, No.-10 copper wires and match a three-wire receptacle of NEMA Type 10-30R. 8. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. DIRECT WIRE Preparing the wire: Three-wire with ground wire: Bare wire cut short. Wire is not used. Dryer is grounded through direct wire cable. 3/4" (1.9 cm) U.L.-listed strain relief to disconnect box 1" (2.5 cm) of wires stripped of insulation 10-gauge, 3-wire or, 10-gauge, 3-wire with ground wire (Romex) NEUTRAL wire (white or center) 3-1/2" (8.9 cm) Strip 3-1/2" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook. Page 10 Where local codes permit connecting cabinet-ground conductor to neutral wire: 4. Loosen or remove center terminal block screw. 5. Place the hooked end of the neutral wire (white or center) of power supply cable under the center screw of the terminal block (hook facing right). Squeeze hooked end together. Tighten screw. 6. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten screws. 7. Tighten strain relief screws. 8. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Three-wire connection...
Three-wire power supply cord must have
three, No.-10 copper wires and match a
three-wire receptacle of NEMA Type
10-30R.
4.
Loosen or remove center
terminal block screw.
6.
Connect the other wires to
outer terminal block screws.
Tighten screws.
7.
Tighten strain relief screws.
8.
Insert tab of terminal block
cover into slot of dryer rear panel.
Secure cover with hold-down
screw.
5.
Connect the neutral wire (white
or center) of power supply cord to
the center, silver-colored terminal
screw of the terminal block.
Tighten screw.
POWER SUPPLY CORD
Three-wire receptacle
NEUTRAL
NEUTRAL
(white or center)
3/4" U.L.-listed
strain relief
This blade connected
to this conductor.
ring
terminals
spade
terminals with
upturned ends
Where local codes permit
connecting cabinet-ground conductor to neutral wire:
Where local codes permit
connecting cabinet-ground conductor to neutral wire:
4.
Loosen or remove center
terminal block screw.
7.
Tighten strain relief screws.
8.
Insert tab of terminal block cover
into slot of dryer rear panel. Secure
cover with hold-down screw.
6.
Place the hooked ends of the
other power supply cable wires
under the outer terminal block
screws (hook facing right). Squeeze
hooked ends together.
Tighten
screws.
5.
Place the hooked end of the
neutral wire (white or center) of
power supply cable under the center
screw of the terminal block (hook
facing right). Squeeze hooked end
together. Tighten screw.
DIRECT WIRE
Preparing the wire:
Strip 3-1/2" (8.9 cm) of
outer covering from
end of cable. Strip
insulation back
1" (2.5 cm). If using
3-wire cable with
ground wire, cut bare
wire even with outer
covering.
Shape
ends of
wires into
a hook.
10-gauge, 3-wire or,
10-gauge, 3-wire with
ground wire (Romex)
3/4" (1.9 cm)
U.L.-listed strain
relief
Three-wire with ground wire:
Bare wire cut short. Wire is not
used. Dryer is grounded through
direct wire cable.
to
disconnect
box
NEUTRAL wire
(white or center)
1" (2.5 cm)
of wires
stripped of
insulation
3-1/2" (8.9 cm)