Xerox 6180N FreeFlow® Print Server MICR User Guide - Page 16

While this, the adjacent field spacing does not compensate for this error.

Page 16 highlights

NOTE: 600 dpi PCL fonts must not be used with a 300 dpi queue or with any 300 dpi resources. The resolution mismatch causes characters to be one dot further apart than is nominal. While this spacing meets industry standards, a high reject rate can result if the adjacent field spacing does not compensate for this error. You can use the PCL Unit of Measure command to set the PCL Unit to 600 (for example, &u600D). Alternatively, you can override the resolution to 600 dpi in the queue. Refer to "Setting the font resolution," later in this chapter, for information on setting the resolution in the queue. 12 MICR User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

12
MICR User Guide
NOTE:
600 dpi PCL fonts must not be used with a 300 dpi queue
or with any 300 dpi resources.
The resolution mismatch causes
characters to be one dot further apart than is nominal.
While this
spacing meets industry standards, a high reject rate can result if
the adjacent field spacing does not compensate for this error.
You can use the PCL Unit of Measure command to set the PCL
Unit to 600 (for example, <ESC>&u600D). Alternatively, you can
override the resolution to 600 dpi in the queue. Refer to “Setting
the font resolution,” later in this chapter, for information on setting
the resolution in the queue.