Xerox 7300N Service Manual - Page 51

NVRAM Access, Service Diagnostics Tests and Functions Table, cont'd.

Page 51 highlights

Service Diagnostics Tests and Functions Table (cont'd.) Menu Item Front Panel Display Results Functional Definition ATS Gauge Calibration - Verifies ATS Calibration. FOR ENGINEERING USE ONLY. Edit Gauge Data Enter Thickness: nn Microns Execute Gauge Measurement Insert thickness gauge, then press OK Test Fault - try again! Gauge Calibration Passed / Failed You may need to cycle power Gauge Measurement Results Cal. Result: Passed / Non-Paper ADC Error / Thickness Error / Slant Error / Sensor ADC Error / Sensor Failure / Unknown Calc. Values: (mV/um) 1=n.n 2=n.n 3=n.n AVE=n.n Where 1.40mV/micron is the standard sensivity value. No Paper Samples: 1=nnV, 2=nnV, 3=nnV, CHK=nnV Paper Samples: 1=nnV, 2=nnV, 3=nnV, CHK=nnV, Measured samples without and with media present in sensor. No-Paper Samples = 3.33V. No Paper Average: 1=nnV, 2=nnV, 3=nnV, CHK=nnV Paper Average: 1=nnV, 2=nnV, 3=nnH, CHK=nnV Measured averages without and with media present in sensor. No-Paper Average = 3.33V ATS Anvil Adjustment- Adjust anvil and read media voltage. See "Automatic Thickness Sensor (ATS) Calibration Procedure" on page 4-118 for procedures on adjusting the ATS Anvil. Anvil Measure: V=n.nn FOR ENGINEERING USE ONLY NVRAM Access - This menu lets you read, set or reset selected NVRAM address locations. PostScript NVRAM Reset PostScript will now reset NVRAM Are you sure? Yes No Exiting Service Diagnostics Restores the printers setup values to their factory defaults. For more information on resetting NVRAM, See "PostScript NVRAM Resets" on page 4-122. CRU Counter Read Total Pages = nnn Fuser pages = nnn Trans.Belt Images = nnn Error Messages and Codes 2-35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277

Error Messages and Codes
2-35
ATS Gauge Calibration
- Verifies ATS Calibration. FOR ENGINEERING USE ONLY.
Edit Gauge
Data
Enter Thickness: nn Microns
<Press
Down
for more data>
<Press
Info
for help>
<Press
Back
or
Cancel
to exit>
Execute Gauge
Measurement
Insert thickness gauge, then press OK
Test Fault - try again!
Gauge Calibration Passed / Failed
You may need to cycle power
<Press
Back
or
Cancel
to abort>
Gauge Measurement Results
Cal. Result: Passed / Non-Paper ADC
Error / Thickness Error / Slant Error /
Sensor ADC Error / Sensor Failure /
Unknown
<Press
Down
for more data>
<Press
Info
for help>
<Press
Back
or
Cancel
to exit>
Calc. Values: (mV/um)
1=n.n
2=n.n
3=n.n
AVE=n.n
<Press
Down
for more data>
Where 1.40mV/micron is the
standard sensivity value.
<Press
Info
for help>
<Press
Back
or
Cancel
to exit>
No Paper Samples:
1=nnV, 2=nnV,
3=nnV, CHK=nnV
Paper Samples: 1=nnV, 2=nnV,
3=nnV, CHK=nnV,
<Press
Down
for more data>
Measured samples without and
with media present in sensor.
No-Paper Samples = 3.33V.
<Press
Info
to toggle display>
<Press
Back
or
Cancel
to exit>
No Paper Average:
1=nnV, 2=nnV,
3=nnV, CHK=nnV
Paper Average: 1=nnV, 2=nnV,
3=nnH, CHK=nnV
<Press
Down
for more data>
Measured averages without and
with media present in sensor.
No-Paper Average = 3.33V
<Press
Info
to toggle display>
<Press
Back
or
Cancel
to exit>
ATS Anvil Adjustment
- Adjust anvil and read media voltage. See “Automatic Thickness
Sensor (ATS) Calibration Procedure” on page 4-118 for procedures on adjusting the ATS
Anvil.
Anvil Measure: V=n.nn
FOR ENGINEERING USE ONLY
<Press
OK
to repeat test>
<Press
Cancel
to exit>
NVRAM Access
- This menu lets you read, set or reset selected NVRAM address
locations.
PostScript
NVRAM Reset
PostScript will now reset NVRAM
Are you sure?
Yes
No
Exiting Service Diagnostics
Restores the printers setup values
to their factory defaults. For more
information on resetting NVRAM,
See “PostScript NVRAM Resets”
on page 4-122.
CRU Counter
Read
Total Pages = nnn
Fuser pages = nnn
Trans.Belt Images = nnn
<Press
Down
for more data>
Service Diagnostics Tests and Functions Table
(cont'd.)
Menu Item
Front Panel Display Results
Functional Definition