Yamaha Tio1608-D2 Tio1608-D2 Owners Manual - Page 13

LINK/ACT], NOTICE, English

Page 13 highlights

English 5 Dante [PRIMARY]/[SECONDARY] etherCON CAT5 connector that connects the unit to a Dante device, such as a NY64-D digital audio interface card. When DIP switch 4 is set to the daisy-chain connection position (i.e., up position), signals received on one connector are sent out via the other connector. When DIP switch 4 is set to the redundant connection position (i.e., down position), the [SECONDARY] functions as a backup and carries the same signals as the [PRIMARY]. If for some reason signals cannot be carried over the [PRIMARY] (for example, because the cable becomes damaged or disconnected, or because the network switch malfunctions), the unit switches to the [SECONDARY]. NOTICE Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable shield by conductive tape or comparable means. NOTE • We recommend using RJ-45 plugs that are compatible with Neutrik etherCON CAT5 connectors. You can also use cables with standard RJ-45 plugs. • The maximum length of cable that can be used varies depending on the type of cable. When using CAT5e cables, data can be sent between devices that are connected by up to 100 m of cable. 6 [LINK/ACT] Indicate the status of the signals carried by the [PRIMARY] and [SECONDARY]. If an indicator is flashing quickly, the corresponding Ethernet cable is not connected properly. 7 [1G] Indicate the connection status of the [PRIMARY] and [SECONDARY]. If an indicator is lit, the corresponding connector is connected to a Gigabit Ethernet network. Device features - 13 - Tio1608-D2 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Device features
-
13
-
Owner’s Manual
Tio1608-D2
English
5
Dante [PRIMARY]/[SECONDARY]
etherCON CAT5 connector that connects the unit to a
Dante device, such as a NY64-D digital audio interface
card. When DIP switch 4 is set to the daisy-chain
connection position (i.e., up position), signals
received on one connector are sent out via the other
connector. When DIP switch 4 is set to the redundant
connection position (i.e., down position), the
[SECONDARY] functions as a backup and carries the
same signals as the [PRIMARY]. If for some reason
signals cannot be carried over the [PRIMARY] (for
example, because the cable becomes damaged or
disconnected, or because the network switch
malfunctions), the unit switches to the [SECONDARY].
6
[LINK/ACT]
Indicate the status of the signals carried by the
[PRIMARY] and [SECONDARY]. If an indicator is
flashing quickly, the corresponding Ethernet cable is
not connected properly.
7
[1G]
Indicate the connection status of the [PRIMARY] and
[SECONDARY]. If an indicator is lit, the corresponding
connector is connected to a Gigabit Ethernet network.
NOTICE
Use an STP (Shielded T
w
isted Pair) cable to prevent
electromagnetic interference. Make s
u
re that the metal parts of
the pl
u
gs are electrically connected to the STP cable shield by
cond
u
ctive tape or comparable means.
NOTE
We recommend
u
sing RJ-45 pl
u
gs that are compatible
w
ith
N
e
u
trik etherCO
N
CAT5 connectors. Yo
u
can also
u
se
cables
w
ith standard RJ-45 pl
u
gs.
The maxim
u
m length of cable that can be
u
sed varies
depending on the type of cable. When
u
sing CAT5e cables,
data can be sent bet
w
een devices that are connected by
u
p
to 100 m of cable.