Yamaha Tio1608-D2 Tio1608-D2 Owners Manual - Page 18

Warnings, Information Message

Page 18 highlights

How to read the indicators Warnings The indicators will light and/or flash as shown until the cause is resolved. If the green [SYNC] is unlit, the unit's clock is unconfirmed. [SYNC] Description Clock settings are incorrect. Off Flashing Unit not connected to Dante network. Possible Solution Check the clock leader and sampling frequency settings of the Tio1608-D2 and Dante Controller. Make sure the cables are not damaged and that they are connected properly. Off Flashes 2 times Cable wiring is wrong; cannot find other Dante devices. Check the wiring of the Ethernet cables. Off Flashes 3 times If the green indicator is flashing, the unit is the clock leader. If the green indicator is lit, the unit is the clock follower and the clock is synchronized. [SYNC] Description Possible Solution Device that is not Gigabit Ethernet compatible is connected. To use Dante to send and receive digital audio, make sure your devices are Gigabit Ethernet compatible. Lit or flashing Lit When using a redundancy network, Check the connections of the network [SECONDARY] is sending/receiving audio. connected to the [PRIMARY]. Lit or flashing Flashing When using a redundancy network, error was detected on the [SECONDARY]. Check the connections of the network connected to the [SECONDARY]. Lit or flashing Flashes 2 times Information Message The indicators will remain lit and/or flashing cyclically to report the status. If the orange [SYNC] is unlit, the unit is operating normally. If the green [SYNC] is unlit, the unit's clock is unconfirmed. [SYNC] Description Synchronizing on a Dante network. Off Lit Waiting to receive setting data. The unit is functioning correctly as the word clock leader. Possible Solution Please wait until started has completed or until the unit has finished synchronization. It may take up to 45 seconds for completion. If START UP MODE is set to REFRESH on the Tio1608-D2 unit, the input/output will be muted until the unit receives setting data after it starts up. The unit is operating as the word clock leader. Flashing Off Lit Off Tio1608-D2 Owner's Manual The unit is functioning correctly as the word The unit is operating as the clock follower clock follower. and the clock is synchronized. - 18 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

How to read the indicators
-
18
-
Owner’s Manual
Tio1608-D2
Warnings
The indicators
w
ill light and/or flash as sho
w
n
u
ntil the ca
u
se is resolved.
If the green [SY
N
C] is
u
nlit, the
u
nit’s clock is
u
nconfirmed.
If the green indicator is flashing, the
u
nit is the clock leader.
If the green indicator is lit, the
u
nit is the clock follo
w
er and the clock is synchronized.
Information Message
The indicators
w
ill remain lit and/or flashing cyclically to report the stat
u
s.
If the orange [SY
N
C] is
u
nlit, the
u
nit is operating normally.
If the green [SY
N
C] is
u
nlit, the
u
nit's clock is
u
nconfirmed.
[SYNC]
Description
Possible Solution
Off
Flashing
Clock settings are incorrect.
Check the clock leader and sampling
freq
u
ency settings of the Tio160
8
-D2 and
Dante Controller.
Off
Flashes 2 times
Unit not connected to Dante net
w
ork.
Make s
u
re the cables are not damaged and
that they are connected properly.
Off
Flashes 3 times
Cable
w
iring is
w
rong; cannot find other
Dante devices.
Check the
w
iring of the Ethernet cables.
[SYNC]
Description
Possible Solution
Lit or flashing
Lit
Device that is not Gigabit Ethernet
compatible is connected.
To
u
se Dante to send and receive digital
a
u
dio, make s
u
re yo
u
r devices are Gigabit
Ethernet compatible.
Lit or flashing
Flashing
When
u
sing a red
u
ndancy net
w
ork,
[SECO
N
DARY] is sending/receiving a
u
dio.
Check the connections of the net
w
ork
connected to the [PRIMARY].
Lit or flashing
Flashes 2 times
When
u
sing a red
u
ndancy net
w
ork, error
w
as detected on the [SECO
N
DARY].
Check the connections of the net
w
ork
connected to the [SECO
N
DARY].
[SYNC]
Description
Possible Solution
Off
Lit
Synchronizing on a Dante net
w
ork.
Please
w
ait
u
ntil started has completed or
u
ntil the
u
nit has finished synchronization. It
may take
u
p to 45 seconds for completion.
Waiting to receive setting data.
If START UP MODE is set to REFRESH on
the Tio160
8
-D2
u
nit, the inp
u
t/o
u
tp
u
t
w
ill be
m
u
ted
u
ntil the
u
nit receives setting data after
it starts
u
p.
Flashing
Off
The
u
nit is f
u
nctioning correctly as the
w
ord
clock leader.
The
u
nit is operating as the
w
ord clock
leader.
Lit
Off
The
u
nit is f
u
nctioning correctly as the
w
ord
clock follo
w
er.
The
u
nit is operating as the clock follo
w
er
and the clock is synchronized.