Zenith SL-5610-WH-B User Guide - Page 1

Zenith SL-5610-WH-B - Heath - 110 Degree Motion Sensing Security Light Manual

Page 1 highlights

Motion Sensor Entryway Light OPERATION Mode: Test Auto Manual On-Time 5 Seconds 1, 5, or 10 Min Until Dawn* Works: Day Night xx x x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. Models SL-5610/15 The Heath®/Zenith Motion Sensor Entryway Light turns on up to 60 watts of incandescent light when motion is detected and then, after a selectable time period, automatically turns the light off. The built-in photocell keeps the light off during daylight hours. TEST Put the ON-TIME switch on the bottom ON-TIME of the sensor in the TEST position. 10 5 1 TEST AUTO Put the ON-TIME switch in the 1, 5, or 10 minute position. ON-TIME 10 5 1 TEST This package includes: Sensor globe (SL-5615) or jar (SL-5610) Entryway Light 2 Screws 2 Wire Connectors MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE. 1 Second OFF then... Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. ... back on. Mounting Nut and Stem Mounting Strap and Grounding Wire Requirements • The Entryway Light requires 120-volts AC. • If you want to use Manual Override, the light must be wired through a switch. • Some codes require installation by a qualified electrician. Mode Switching Summary TEST AUTO MANUAL MODE Move ON-TIME Switch to 1, 5, or 10 minutes Flip light switch off for one second then back on* * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2007 HeathCo LLC 595-5498-09

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

© 2007 HeathCo LLC
595-5498-09
Motion Sensor
Entryway Light
Models SL-5610/15
The Heath
®
/Zenith Motion Sensor Entryway Light turns
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
Sensor
Entryway Light
Mounting Nut and Stem
2 Wire
Connectors
2 Screws
Mounting Strap and
Grounding Wire
globe
(SL-5615)
or
jar
(SL-5610)
Requirements
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
Some codes require installation by a qualified
electrician.
This package includes:
OPERATION
* resets to Auto Mode at dawn.
Note:
When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
MANUAL MODE
ON-TIME
10 5 1
TEST
10 5 1
TEST
ON-TIME
TEST
... back on.
AUTO
1 Second
OFF
then...
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Min
x
Manual
Until Dawn*
x