3Com 3C81600 User Guide - Page 37

B, Technical Specifications, SuperStack 3 Advanced RPS Chassis

Page 37 highlights

B TECHNICAL SPECIFICATIONS SuperStack 3 Advanced RPS Chassis Physical Dimensions (chassis empty) Height: 90 mm (2U) x Width: 440 mm (17.3 in.) x Depth 370 mm (14.5 in.) Weight: 8.5 Kg (18.7 lb) Environmental Requirements Operating Temperature 0° to 50°C (32° to 122°F) Storage Temperature -10° to +70°C (14° to 158°F) Operating Humidity 10 to 95% relative humidity, non-condensing Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13). Safety Agency Certifications IEC 60950, UL 1950, EN60950, CSA 22.2 No. 950 EMC Emissions CISPR22 Class A EN55022 Class A FCC Part 15 Subpart B Class A ICES-003 Class A VCCI Class A AS/NZS3548 Class A CNS13438 Class A EN61000-3-2 EN61000-3-3 Immunity EN55024 Output Power 480 W (650 W when used with Type 3 Power Modules) Power Supply (chassis with no Power Module installed) AC Line Frequency 50/60 Hz Input Voltage Options 115/230 VAC Current Rating 115 V 12 amps 230 V 5 amps

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

B
T
ECHNICAL
S
PECIFICATIONS
SuperStack 3 Advanced RPS Chassis
Physical Dimensions
(chassis
empty)
Height: 90 mm (2U) x Width: 440 mm (17.3 in.) x Depth
370 mm (14.5 in.)
Weight: 8.5 Kg (18.7 lb)
Environmental Requirements
Operating Temperature
0
°
to 50
°
C (32
°
to 122
°
F)
Storage Temperature
10
°
to +70
°
C (14
°
to 158
°
F)
Operating Humidity
10 to 95% relative humidity, non-condensing
Standards
EN60068 to 3Com schedule (Package testing: paras 2.1,
2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2,
2.30 and 2.13).
Safety
Agency Certifications
IEC 60950, UL 1950, EN60950, CSA 22.2 No. 950
EMC
Emissions
CISPR22 Class A
EN55022 Class A
FCC Part 15 Subpart B Class A
ICES-003 Class A
VCCI Class A
AS/NZS3548 Class A
CNS13438 Class A
EN61000-3-2
EN61000-3-3
Immunity
EN55024
Output Power
480 W (650 W when used with Type 3 Power Modules)
Power Supply
(chassis with no Power Module installed)
AC Line Frequency
50/60 Hz
Input Voltage Options
115/230 VAC
Current Rating
115 V 12 amps
230 V 5 amps