Adaptec 133U2 User Guide - Page 154

Viewing Subsystem Status Details

Page 154 highlights

Adaptec CI/O Management Software User's Guide The following section explains the information that appears when you click the Component Status tab on the Enclosure Properties dialog box. Viewing Subsystem Status Details To view detailed information on temperature sensors, fans or power supplies, click the Component Status tab in the Information dialog box as shown in Figure B-2. Figure B-2. Component Status Dialog Box Temperature Sensors The status of the temperature sensors in the enclosure is displayed in the Temperature Sensors list box. Adaptec CI/O Management Software supports both threshold indicators and temperture indicators. If the enclosure contains at least one temperature indicator, the actual temperature is displayed. If the enclosure contains a threshold indicator, a reading of Within Range or Out of Range will be displayed for each present indicator. If the temperature is out of normal range, the temperature indicator icon will be displayed with a red exclamation mark next to it. B-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

B-4
Adaptec CI/O Management Software User’s Guide
The following section explains the information that appears when
you click the Component Status tab on the Enclosure Properties
dialog box.
Viewing Subsystem Status Details
To view detailed information on temperature sensors, fans or power
supplies, click the
Component Status
tab in the Information dialog
box as shown in Figure B-2.
Temperature Sensors
The status of the temperature sensors in the enclosure is displayed
in the Temperature Sensors list box. Adaptec CI/O Management
Software supports both threshold indicators and temperture
indicators. If the enclosure contains at least one temperature
indicator, the actual temperature is displayed. If the enclosure
contains a threshold indicator, a reading of
Within Range
or
Out of
Range
will be displayed for each present indicator. If the
temperature is out of normal range, the temperature indicator icon
will be displayed with a red exclamation mark next to it.
Figure B-2. Component Status Dialog Box