Adaptec 133U2 User Guide - Page 156

Identification of Events

Page 156 highlights

Adaptec CI/O Management Software User's Guide Identification of Events The Adaptec CI/O Management Software identifies events related to each SAF-TE enclosure. Each enclosure is identified by a unique address (bus/host adapter, channel, SCSI ID, and LUN). This address is specified for all events logged for that particular enclosure to allow easy identification of the enclosure. Events for SAF-TE Enclosures The following is a list of events that may be generated for SAF-TE enclosures: 1 Enclosure found [ SAF-TE : unique address]- Posted for each found and successfully initialized SAF-TE enclosure, an event identifying the unique address is generated. 2 Enclosure not responding [ SAF-TE : unique address]- Posted for each unrecoverable error that occurred when communicating with a SAF-TE enclosure. Adaptec CI/O Management Software will stop polling this device until communication is recovered. On recovery, monitoring of this device will start automatically. 3 Enclosure removed from bus [ SAF-TE : unique address]- Posted when an enclosure device is removed from the bus (for example, it was physically removed, power was switched off, etc). 4 Device id=SCSI_ID slot#=slot_ number inserted [ SAF-TE : unique address]- When a device is inserted into a SAF-TE enclosure slot, this event is posted. Adaptec CI/O Management Software will automatically perform a rescan on the controller to which the SAF-TE enclosure is attached. 5 Device id=SCSI_ID slot#=slot_number removed [ SAF-TE : unique address]- Posted when a device is removed from a SAF-TE enclosure slot. If the removed drive is SINGLE, Adaptec CI/O Management Software will automatically perform a rescan. If the removed drive is an array member, Adaptec CI/O Management Software will automatically start a reconstruct, provided there is at least one dedicated or pool spare. B-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

B-6
Adaptec CI/O Management Software User’s Guide
Identification of Events
The Adaptec CI/O Management Software identifies events related
to each SAF-TE enclosure. Each enclosure is identified by a unique
address (bus/host adapter, channel, SCSI ID, and LUN). This
address is specified for all events logged for that particular
enclosure to allow easy identification of the enclosure.
Events for SAF-TE Enclosures
The following is a list of events that may be generated for SAF-TE
enclosures:
1
Enclosure found [ SAF-TE : unique address]
— Posted for each
found and successfully initialized SAF-TE enclosure, an event
identifying the unique address is generated.
2
Enclosure not responding [ SAF-TE : unique address]
— Posted
for each unrecoverable error that occurred when
communicating with a SAF-TE enclosure. Adaptec CI/O
Management Software will stop polling this device until
communication is recovered. On recovery, monitoring of this
device will start automatically.
3
Enclosure removed from bus [ SAF-TE : unique address]
Posted when an enclosure device is removed from the bus (for
example, it was physically removed, power was switched off,
etc).
4
Device id=SCSI_ID slot#=slot_ number inserted [ SAF-TE :
unique address]
— When a device is inserted into a SAF-TE
enclosure slot, this event is posted. Adaptec CI/O
Management Software will automatically perform a rescan on
the controller to which the SAF-TE enclosure is attached.
5
Device id=SCSI_ID slot#=slot_number removed [ SAF-TE :
unique address]
— Posted when a device is removed from a
SAF-TE enclosure slot. If the removed drive is SINGLE,
Adaptec CI/O Management Software will automatically
perform a rescan. If the removed drive is an array member,
Adaptec CI/O Management Software will automatically start
a reconstruct, provided there is at least one dedicated or pool
spare.