Adaptec 2400A Installation Guide - Page 55

Installing the Driver in a Existing NetWare4.11 Server, i2opci.nlm, Save parameters and load driver

Page 55 highlights

Adaptec RAID Installation Guide 8 Insert the driver disk you created in Step 1 and run dpt411.bat. This utility copies the necessary files to the C drive. 9 Run install.bat from the C drive. 10 When asked to select a disk driver select i2opci.nlm. Enter the slot number where the controller is installed and press F10. 11 Select Save parameters and load driver. 12 Select Yes to select another driver. 13 Select bkstrosm.ham. Enter the slot number where the controller is installed and press F10. 14 Select Save parameters and load driver. 15 Install any additional drivers and continue the installation. 16 Select Edit startup.ncf. If needed, edit the file so that i2opci.nlm is listed before bkstrosm.ham in your startup.ncf file. 17 Continue with the NetWare installation according to the Novell documentation. 18 Upgrade your NetWare version to the minimum patch level specified by Novell. Installing the Driver in a Existing NetWare 4.11 Server In this scenario, you are integrating an Adaptec RAID controller into an existing NetWare 4.11 server as a secondary controller. To install the driver 1 Upgrade your existing NetWare server to the minimum patch level specified by Novell. 2 Create a driver floppy disk using the Adaptec RAID Installation CD. To create the disk a Insert the Adaptec RAID Installation CD in your drive and a blank floppy disk in the floppy disk drive. b Copy all the files in \packages\netware\4.11\driver to the floppy disk. c Remove the Adaptec RAID Installation CD and the driver floppy disk. 3-20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

3-20
Adaptec RAID Installation Guide
8
Insert the driver disk you created in
Step 1
and run
dpt411.bat
.
This utility copies the necessary files to the
C
drive.
9
Run
install.bat
from the
C
drive.
10
When asked to select a disk driver select
i2opci.nlm
. Enter the
slot number where the controller is installed and press
F10
.
11
Select
Save parameters and load driver
.
12
Select
Yes
to select another driver.
13
Select
bkstrosm.ham
. Enter the slot number where the
controller is installed and press
F10
.
14
Select
Save parameters and load driver
.
15
Install any additional drivers and continue the installation.
16
Select
Edit startup.ncf
. If needed, edit the file so that
i2opci.nlm
is listed before
bkstrosm.ham
in your
startup.ncf
file.
17
Continue with the NetWare installation according to the
Novell documentation.
18
Upgrade your NetWare version to the minimum patch level
specified by Novell.
Installing the Driver in a Existing NetWare 4.11 Server
In this scenario, you are integrating an Adaptec RAID controller into
an existing NetWare 4.11 server as a secondary controller. To install
the driver
1
Upgrade your existing NetWare server to the minimum patch
level specified by Novell.
2
Create a driver floppy disk using the
Adaptec RAID Installation CD
.
To create the disk
a
Insert the
Adaptec RAID Installation CD
in your drive and a
blank floppy disk in the floppy disk drive.
b
Copy all the files in
\packages\netware\4.11\driver
to the
floppy disk.
c
Remove the
Adaptec RAID Installation CD
and the driver