Ariens Hydro Pro Track 32 Owners Manual - Page 27
Clean Battery 926514, Terminals, Replace Fuse 926514, IMPORTANT, WARNING
View all Ariens Hydro Pro Track 32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Clean Battery (926514) WARNING: AVOID INJURY. Read and understand the entire Safety section before proceeding. IMPORTANT: Battery is maintenance-free. Do not tamper with or attempt to open battery. See SERVICE AND ADJUSTMENTS on page 28 for charging procedures. Terminals Keep battery and its terminals clean. IMPORTANT: Remove battery from unit before cleaning. Remove corrosion from battery terminals and cable connections with wire brush, then wash with a weak baking soda solution. After cleaning, apply a thin coat of grease or petroleum jelly to terminals and cable ends to retard corrosion. Replace Fuse (926514) 1. Remove the two screws and the cover plate from beneath the battery. 2. Locate the fuse holder on the wiring harness and remove the fuse. 3. Install a new fuse of the same amprating and type. OS7455 Fuse and fuse holder. Figure 20 4. Replace the cover plate and secure in position with the two screws removed in step 1. NOTE: Make sure the wire harness does not get pinched between the cover plate and the auger housing. Cover plate and mounting screws. Figure 19 OS7450 EN - 27