Recommended Heatsinks for Slot 1 Processors

Page 32 highlights

3. HARDWARE SETUP 2. Connect the P2T-Cable to the CPU thermal sensor connector (TRCPU). NOTE: Recent CPUs support CPU temperature output. Adding P2T-Cable may result in inaccurate measurement. PARALLEL PORT OPTIONAL 1 2 3 4 P3C-E TRCPU TRPWR P3C-E Thermal Sensor Connectors NOTE: If you have a power supply with thermal monitoring, connect its thermal sensor cable to TRPWR. 3.6.5 Recommended Heatsinks for Slot 1 Processors The recommended heatsinks for the Slot 1 processors are those with three-pin fans, such as the ASUS Smart Fan, that can be connected to the motherboard's CPU fan connector. These heatsinks dissipate heat more efficiently and with an optional hardware monitor, they can monitor the fan's RPM and use the alert function with the Intel LANDesk Client Manager (LDCM) or the ASUS PC Probe software. 3. H/W SETUP CPU SECC Heatsink & Fan SECC2 Heatsink & Fan NOTE: The SEPP heatsink and fan (for Intel Celeron processors) is similar to the SECC2 heatsink and fan except that the clamping design is different. 32 ASUS P3C-E User's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

32
ASUS P3C-E User’s Manual
3. HARDWARE SETUP
3.6.5
Recommended Heatsinks for Slot 1 Processors
The recommended heatsinks for the Slot 1 processors are those with three-pin fans,
such as the ASUS Smart Fan, that can be connected to the motherboard’s CPU fan
connector. These heatsinks dissipate heat more efficiently and with an optional hard-
ware monitor, they can monitor the fan’s RPM and use the alert function with the
Intel LANDesk Client Manager (LDCM) or the ASUS PC Probe software.
SECC Heatsink & Fan
SECC2 Heatsink & Fan
NOTE:
The SEPP heatsink and fan (for Intel Celeron processors) is similar to the
SECC2 heatsink and fan except that the clamping design is different.
CPU
3. H/W SETUP
2.
Connect the P2T-Cable to the CPU thermal sensor connector (TRCPU).
NOTE:
Recent CPUs support CPU temperature output. Adding P2T-Cable may
result in inaccurate measurement.
P3C-E Thermal Sensor Connectors
P3C-E
PARALLEL PORT
OPTIONAL
4
3
2
1
TRPWR
TRCPU
NOTE:
If you have a power supply with thermal monitoring, connect its thermal
sensor cable to TRPWR.