Boot menu, Chassis Fan 1/4 Max. Duty Cycle% [100]
View all Asus Z97-A USB 3.1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Chassis Fan 1/4 Max. Duty Cycle(%) [100] Use the or keys to adjust the maximum chassis fan duty cycle. The values range from 20% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will operate at the maximum duty cycle. Chassis Fan 1/4 Middle Temperature [45] Use the or keys to set the value for Chassis Fan Middle Temperature. Chassis Fan 1/4 Middle Duty Cycle(%) [60] Use the or keys to adjust the chassis fan middle duty cycle. The values range from 20% to 100%. Chassis Fan 1/4 Lower Temperature [40] Use the or keys to adjust the chassis fans' lower temperature. The values range from 20% to 75%. Chassis Fan 1/4 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum chassis fan duty cycle. The values range from 20% to 100%. When the chassis temperature is under 40°C, the chassis fan operates at the minimum duty cycle. Allow Fan Stop [Disabled] This item allows your fans to run at 0% duty cycle when the temperature of the source drops below the lower temperature. Configuration options: [Disabled] [Enabled] Anti Surge Support [Enabled] This item allows you to enable or disable the OVP (Over Voltage Protection) and UVP (Under Voltage Protection) functions. This causes the system to automatically shut down when the voltage exceeds the safe range that protects the motherboard's components. Configuration options: [Disabled] [Enabled] ASUS Z97-A/USB 3.1 2-49