Behringer MS-1-BK Quick Start Guide - Page 20

MS-101 MIDI Channel and Note Value, MS-101 SysEx information, MS-101 MIDI

Page 20 highlights

38 MS-101 MS-101 MIDI Channel and Note Value CHANGING THE MIDI CHANNEL The MIDI input and output channel may be changed using the following procedure: 1. Press SHIFT+ HOLD/REST + 8 to enter the setting mode. The LOCATION LED 1 will blink yellow. 2. Press to select pages 1 or 2. The yellow LOCATION LED, shows the current page: 3. Page 1 allows you to select the MIDI input channel, 1 to 16. 4. Page 2 allows you to select the MIDI output channel, 1 to 16. 5. Press STEP switches 1 to 8 to select numeric values from 1 to 8. The current value is indicated by a green LOCATION LED. 6. To access values 9 to 16, press SHIFT + STEP switch 1 to 8. The current value is shown by a red LOCATION LED. Note: If a setting is on the same LED number as the current page LED, then the LED will flash alternately between the yellow page color and the green or red parameter color. 7. Press SHIFT + HOLD/REST + 8 to exit the setting mode, and save any parameter changes. CHANGING THE SEQUENCER NOTE VALUE The Note value used in the Sequencer may be changed using the following procedure: 1. Press PLAY/STOP to play the current pattern. 2. Press and hold the PATTERN/BANK switch and adjust the TEMPO control. Listen to the change in note value. 3. The LOCATION LEDs will show the current note value in yellow, from 1 to 8 as follows: 1: 1/1 note 2: . 1/2 note 3: 1/2 note 4: . 1/4 note 5: 1/4 note 6: . 1/8 note 7: 1/8 note 8: 1/16 note 4. Repeat this procedure at any time to change the note value. ADSR Envelope The stages of the ADSR envelope are shown in this simplified diagram below. The envelope can control the VCA level, the VCF cut-off frequency, and Pulse Width modulation of the VCO. Attack Decay Time Time Release Time Env Level Key Gate Key Pressed Sustain Level Time Key Released MS-101 SysEx information SYSTEM EXCLUSIVE COMMANDS Some MS-101 parameters can be changed using MIDI system exclusive (SysEx) commands. A MIDI utility such as MIDI OX can be used to send the SysEx command data string to the MS-101 using the USB MIDI connection between the computer and the MS-101. Please see the MS-101 section on our website for more details of the SysEx commands. MS-101 MIDI Channel Message SysRT Status 8n 9n Bn Bn En F8 FA FB FC Second Third kk vv kk vv 5 vv 7B -- bb bb -- -- -- -- -- -- -- -- MIDI Examples Note: (MIDI Input Channel 1) Function Note On Note Off Select glide time MIN Select glide time MAX All note off Command 90 3C 64 80 3C 40 B0 05 00 B0 05 7F B0 7B Parameter [0,7F] [0,7F] [0,7F] [0,3FFF] Description Note Off Note On Glide Time All Note Off Pitch Bend Timing Clock Start Continue Stop Quick Start Guide 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

38
MS-101
Quick Start Guide
39
MS-101 MIDI Channel and Note Value
CHANGING THE MIDI CHANNEL
The MIDI input and output channel may be changed
using the following procedure:
1.
Press SHIFT+ HOLD/REST + 8 to enter the
setting mode. The LOCATION LED 1 will
blink yellow.
2.
Press <KYBD or STEP> to select pages 1
or 2. The yellow LOCATION LED, shows the
current page:
3.
Page 1 allows you to select the MIDI input
channel, 1 to 16.
4.
Page 2 allows you to select the MIDI output
channel, 1 to 16.
5.
Press STEP switches 1 to 8 to select numeric
values from 1 to 8. The current value is
indicated by a green LOCATION LED.
6.
To access values 9 to 16, press SHIFT + STEP
switch 1 to 8. The current value is shown by a
red LOCATION LED.
Note: If a setting is on the same LED number
as the current page LED, then the LED will
flash alternately between the yellow page
color and the green or red parameter color.
7.
Press SHIFT + HOLD/REST + 8 to
exit the setting mode, and save any
parameter changes.
CHANGING THE SEQUENCER NOTE VALUE
The Note value used in the Sequencer may be
changed using the following procedure:
1.
Press PLAY/STOP to play the current pattern.
2.
Press and hold the PATTERN/BANK switch
and adjust the TEMPO control. Listen to the
change in note value.
3.
The LOCATION LEDs will
show the current note value in yellow, from 1
to 8 as follows:
1:
1/1 note
2:
. 1/2 note
3:
1/2 note
4:
. 1/4 note
5:
1/4 note
6:
. 1/8 note
7:
1/8 note
8:
1/16 note
4.
Repeat this procedure at any time to change
the note value.
Attack
Time
Decay
Time
Sustain Level
Time
Env
Level
Key
Gate
Release
Time
Key Pressed
Key Released
ADSR Envelope
The stages of the ADSR envelope are shown in this simplified diagram
below. The envelope can control the VCA level, the VCF cut-off frequency,
and Pulse Width modulation of the VCO.
MS-101 SysEx information
SYSTEM EXCLUSIVE COMMANDS
Some MS-101 parameters can be changed using MIDI system exclusive (SysEx)
commands. A MIDI utility such as MIDI OX can be used to send the SysEx command
data string to the MS-101 using the USB MIDI connection between the computer
and the MS-101.
Please see the MS-101 section on our website for more details of the
SysEx commands.
MS-101 MIDI
MIDI Examples
Note: (MIDI Input Channel 1)
Status
Second
Third
Parameter
Description
Channel
Message
8n
kk
vv
[0,7F]
Note Off
9n
kk
vv
[0,7F]
Note On
Bn
5
vv
[0,7F]
Glide Time
Bn
7B
--
All Note Off
En
bb
bb
[0,3FFF]
Pitch Bend
SysRT
F8
--
--
Timing Clock
FA
--
--
Start
FB
--
--
Continue
FC
--
--
Stop
Function
Command
Note On
90 3C 64
Note Off
80 3C 40
Select glide time MIN
B0 05 00 
Select glide time MAX
B0 05 7F
All note off
B0 7B