Belkin F1DE101H User Manual - Page 17
Configuration via Serial Interface - ip address
View all Belkin F1DE101H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
section 2-4 Configuration via Serial Interface Installation To configure the RIPM via serial interface, a null modem cable is required 1 (provided). Connect the null modem cable to the "Serial 01" port on the RIPM and the other end to the serial port on the computer. The serial interface needs to be adjusted with the parameters as shown below: 2 Parameter Value 3 Bits/second 115200 4 Data bits 8 Parity no 5 Stop bits 1 Flow control none 6 Use a terminal software program (e.g., HyperTerminal) to connect to the RIPM. Reset the RIPM and immediately press the "ESC" key. You will see a "=>" prompt. Enter the command "config" and press the "ENTER" key. You will be asked to adjust the IP auto configuration, the IP address, the net mask, and the default gateway. Pressing the "ENTER" key without entering values does not change settings. The gateway value has to be set to "0.0.0.0" (for no gateway) or any other value for the IP address of the gateway. After the confirmation, the RIPM performs a reset using the new values as set before. 14