Brother International IntelliFax-4750 Service Manual - Page 129
These selectors set the short-circuiting time length of the telephone line La or Lb to ground.
![]() |
View all Brother International IntelliFax-4750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Selector No. 1 | 4 5 6 7 8 WSW04 (TRANSFER facility setting) Function Setting and Specifications Not used. Earth time length for earth function Break time length for flash function No. 5 6 00 01 10 11 No. 7 8 00 01 10 11 : 200 ms : 300 ms : 500 ms : 700 ms : 80 ms : 110 ms : 250 ms : 500 ms NOTE: Selectors 5 through 8 are not applicable in those countries where no transfer facility is supported. l Selectors 5 and 6: Earth time length for earth function These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground. This setting is effective only when the earth function is selected for the R key by using the function switch. l Selectors 7 and 8: Break time length for flash function These selectors set the break time length. This setting is effective only when the flash function is selected for the R key by using the function switch. V - 15
![](/manual_guide/products/brother-international-8750p-service-manual-4676792/129.png)