e.g., U.S.A., The WSW08 is not applicable in those countries where no dial tone detection is supported
View all Brother International IntelliFax-4750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
WSW08 (Dial tone setting 2) Selector No. Function 1 | 1st dial tone detection time 3 length 4 Time-out length for 1st and 2nd dial tone detection 5 6 Detection level of 1st dial tone | and busy tone before dialing 8 Setting and Specifications No. 1 2 3 000: 001: 010: 011: 100: 101: 110: 111: 50 ms 210 ms 500 ms 800 ms 900 ms 1.5 sec. 2.0 sec. 2.5 sec. No. 4 5 0 0 : 10 sec. 0 1 : 20 sec. 1 0 : 15 sec. 1 1 : 30 sec. No. 6 7 8 000: 001: 010: 011: 100: 101: 110: 111: -21 dBm -24 dBm -27 dBm -30 dBm -33 dBm -36 dBm -39 dBm -42 dBm NOTE: The WSW08 is not applicable in those countries where no dial tone detection is supported, e.g., U.S.A. l Selectors 1 through 3: 1st dial tone detection time length Upon detection of the 1st dial tone for the time length set by these selectors, the equipment starts dialing. This setting is effective only when selectors 1 through 3 of WSW05 are set to "1,1,1." l Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection These selectors set the time-out length for the 1st and 2nd dial tone detection so that the equipment waits dial tone input for the specified time length and disconnects itself from the line when no dial tone is inputted. V - 21