Brother International KE-430D Instruction Manual - English - Page 62

Table Of Error Codes, Danger - service manual

Page 62 highlights

9. TABLE OF ERROR CODES 9. TABLE OF ERROR CODES DANGER Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury. If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem. Switch-related errors Code Cause and remedy E025 E035 Foot switch is depressed to the 2nd step. Turn off the power and check the foot switch. Foot switch is depressed to the 1st step. Turn off the power and check the foot switch. E050 E051 E055 Machine head tilting was detected after the power was turned on. Turn off the power, and then return the machine head to its original position. Check that connector P8 on the main P.C. board is properly connected. Machine head tilting was detected while the sewing machine was operating. Turn off the power, and then check that connector P8 on the main P.C. board is properly connected. Machine head tilting was detected when the power was turned on. Turn off the power, and then return the machine head to its original position. Check that connector P8 on the main P.C. board is properly connected. E065 An operation panel key was still being pressed when the power was turned on, or key is faulty. Turn off the power and check the operation panel. Upper shaft motor-related errors Code E100 E110 E111 E120 Cause and remedy Sewing machine has continued to be used for a certain period after the "GREASEUP" notification appears without the grease being applied (without the reset procedure being carried out). Apply grease and then carry out the reset procedure. (Refer to the service manual for the reset procedure.) Needle up stop position error. Turn the pulley to align the index mark with the needle up stop position. Upper shaft did not stop at the needle up stop position when the sewing machine stopped. Turn the pulley to align the index mark with the needle up stop position. Needle drop signal could not be detected. Turn off the power, and then check the synchronizer connection. E121 E130 E131 Thread trimming was not completed. Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn. Sewing machine motor stopped abnormally or synchronizer is not connected correctly. Turn off the power, and then turn the machine pulley to check if the machine has locked up. Check that connectors P4 and P5 on the power supply motor P.C. board are properly connected. Synchronizer is not connected correctly. Turn off the power, and then check that connector P5 on the power supply motor P. C. board is properly connected. E132 E133 E150 Problem detected with sewing machine motor operation. Turn off the power, and then check that connector P4 on the power supply motor P.C. board is properly connected. Sewing machine motor stopping position is incorrect. Turn off the power, and then check that connector P5 on the power supply motor P.C. board is properly connected. Sewing machine motor is overheating, or temperature sensor is faulty. Turn off the power, and then check the sewing machine motor. (When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle operation), the upper shaft motor may overheat and the "E150" error code may be generated.) 55 KE-430D, BE-438D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

9. TABLE OF ERROR CODES
55
KE-430D, BE-438D
9. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Cause and remedy
E025
Foot switch is depressed to the 2nd step.
Turn off the power and check the foot switch.
E035
Foot switch is depressed to the 1st step.
Turn off the power and check the foot switch.
E050
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P8 on the main P.C. board is properly connected.
E051
Machine head tilting was detected while the sewing machine was operating.
Turn off the power, and then check that connector P8 on the main P.C. board is properly connected.
E055
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P8 on the main P.C. board is properly connected.
E065
An operation panel key was still being pressed when the power was turned on, or key is faulty.
Turn off the power and check the operation panel.
Upper shaft motor-related errors
Code
Cause and remedy
E100
Sewing machine has continued to be used for a certain period after the “GREASEUP” notification appears
without the grease being applied (without the reset procedure being carried out).
Apply grease and then carry out the reset procedure. (Refer to the service manual for the reset procedure.)
E110
Needle up stop position error.
Turn the pulley to align the index mark with the needle up stop position.
E111
Upper shaft did not stop at the needle up stop position when the sewing machine stopped.
Turn the pulley to align the index mark with the needle up stop position.
E120
Needle drop signal could not be detected.
Turn off the power, and then check the synchronizer connection.
E121
Thread trimming was not completed.
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn.
E130
Sewing machine motor stopped abnormally or synchronizer is not connected correctly.
Turn off the power, and then turn the machine pulley to check if the machine has locked up.
Check that connectors P4 and P5 on the power supply motor P.C. board are properly connected.
E131
Synchronizer is not connected correctly.
Turn off the power, and then check that connector P5 on the power supply motor P. C. board is properly
connected.
E132
Problem detected with sewing machine motor operation.
Turn off the power, and then check that connector P4 on the power supply motor P.C. board is properly
connected.
E133
Sewing machine motor stopping position is incorrect.
Turn off the power, and then check that connector P5 on the power supply motor P.C. board is properly
connected.
E150
Sewing machine motor is overheating, or temperature sensor is faulty.
Turn off the power, and then check the sewing machine motor.
(When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle
operation), the upper shaft motor may overheat and the “E150” error code may be generated.)