Brother International RH-981A Instruction Manual - Spanish - Page 29
Connecting the connectors, Blue Black
View all Brother International RH-981A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
3-17-5. Connecting the connectors 3023Q 3. INSTALLATION 1. Insert the 3-pin connectors [8], [9] and [10] of the valve harness into the solenoid valves of the valve unit (1) so that the label numbers match. 2. Insert the 15-pin connector (2) into the connector of the indexer cord (3). 3. Open the rear cover (4) of the control box. 4. Insert the connector (5) of the indexer cord (3) in the position shown in the illustration. 5. Secure the cord with the cord clamp. 3024Q 6. Insert the two pins of limit switch (R) (6) and the two pins of limit switch (L) (7) into the 15-pin connector terminals with matching numbers. 7. Connect the three pins of the cylinder sensor (8) into the 15-pin connector so that the cable colors match the connector numbers as given in the table below. * If the cable colors are red, white and black, refer to the colors in brackets. Note: First disconnect the connector before inserting the pins, and then after inserting the pins, re-connect the connector. Limit switch (R) (6) Limit switch (L) (7) Cylinder sensor (8) Switch pin No. 7 12 10 15 Cable color White Black White Black Brown (Red) Black (White) Blue (Black) 15-pin Connector 7 12 10 15 4 9 14 8. Secure the cable with the cable clamp (9). 3025Q RH-981A 22