Campbell Scientific WINDSONIC1 WINDSONIC 2-D Sonic Wind Sensors - Page 26
Report the total of diag = 1., Report the total of diag = 2., Report the total of diag = 4
View all Campbell Scientific WINDSONIC1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
WindSonic Two-Dimensional Sonic Anemometer 8: If (XF) (P89) 1: 3 X Loc [ ws_diag ] 2: 2 3: 0 F 4: 19 Set Intermed. Proc. Disable Flag High (Flag 9) 9: Wind Vector (P69) 1: 1 Reps 2: 0 Samples per Sub-Interval 3: 0 S, theta(1), sigma(theta(1)) with polar sensor 4: 2 Wind Speed/East Loc [ wnd_spd ] 5: 1 Wind Direction/North Loc [ wnd_dir ] 10: Totalize (P72) 1: 1 Reps 2: 4 Loc [ samples ] 11: If (XF) (P89) 1: 3 X Loc [ ws_diag ] 2: 1 = 3: 1 F 4: 29 Set Intermed. Proc. Disable Flag Low (Flag 9) ;Report the total of diag = 1. ; 12: Totalize (P72) 1: 1 Reps 2: 4 Loc [ samples ] 13: If (XF) (P89) 1: 3 X Loc [ ws_diag ] 2: 1 = 3: 2 F 4: 29 Set Intermed. Proc. Disable Flag Low (Flag 9) ;Report the total of diag = 2. ; 14: Totalize (P72) 1: 1 Reps 2: 4 Loc [ samples ] 15: If (XF) (P89) 1: 3 X Loc [ ws_diag ] 2: 1 = 3: 4 F 4: 29 Set Intermed. Proc. Disable Flag Low (Flag 9) ;Report the total of diag = 4. ; 16: Totalize (P72) 1: 1 Reps 2: 4 Loc [ samples ] 18