Canon LV-5220 Serial Functional Specification - Page 11

Setting Status Read Command Table, Status read command, 9. Other Status Read Command Table, Error

Page 11 highlights

Expand Serial Command Functional Specification Page 10 of 41 6.8. Setting Status Read Command Table Status read command CR_BBACK [CR] CR_DISP [CR] CR_LOGO [CR] CR_RCODE [CR] CR_LANG [CR] CR_ON-STA [CR] CR_P-MANE [CR] CR_P-MANETIME [CR] CR_FANSPEED [CR] CR_KEYDIS [CR] CR_TERMINAL [CR] CR_STANDBYMODE [CR] CR_POINTER [CR] CR_AUTOSETUP_%1 [CR] CR_FANMODE [CR] Item Read Blue Back setting Read Display setting Read Logo setting Read selected Remote Code Read selected Language Read On Start setting status Read Power Management setting status Read the start time for Power Management Read selected FAN Control Speed Read RC/KEY Prohibit status Read Terminal setting status Read Standby mode setting status Read Pointer setting status Read Auto Setup setting status Read selected Fan mode 6.9. Other Status Read Command Table Status read command CR_SIGNAL [CR] CR_VMUTE [CR] CR_FREEZE [CR] CR_PTIMER [CR] CR_TEMPWARN [CR] CR_TEMPFAIL [CR] Item Read the status if there is signal or no signal Read No Show setting status Read Freeze setting status Read P-Timer operational status Read if sensors are exceeding critical temperature or not Read the temperature when sensors approached critical temperature 7. Error Code Table Error Code ? 000 101 102 103 201 301 302 303 402 Content When receives data that cannot be decoded. Parameter determination error. (Digit number error, and incorrect letter included) Normal Reception. (Not error) The function is not available in the selected Mode. Selected the value is out of range. (Selected value will not be reflected) Command mismatched to the Hardware. (Command for unpopulated option function) When sending command, the increment is maximum value or the decrement is minimum value. Processing image capture. Re-try it again later. Processing Auto setup, not executable. Re-try it again later. Processing Memory Card Viewer. Re-try it again later. Processing PIN Code, not executable. Re-try it again later. Note) this error code for Expand Command, not applicable for Basic Command.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Expand Serial Command Functional Specification
Page 10 of 41
6.8. Setting Status Read Command Table
Status read command
Item
CR_BBACK [CR]
Read Blue Back setting
CR_DISP [CR]
Read Display setting
CR_LOGO [CR]
Read Logo setting
CR_RCODE [CR]
Read selected Remote Code
CR_LANG [CR]
Read selected Language
CR_ON-STA [CR]
Read On Start setting status
CR_P-MANE [CR]
Read Power Management setting status
CR_P-MANETIME [CR]
Read the start time for Power Management
CR_FANSPEED [CR]
Read selected FAN Control Speed
CR_KEYDIS [CR]
Read RC/KEY Prohibit status
CR_TERMINAL [CR]
Read Terminal setting status
CR_STANDBYMODE [CR]
Read Standby mode setting status
CR_POINTER [CR]
Read Pointer setting status
CR_AUTOSETUP_%1 [CR]
Read Auto Setup setting status
CR_FANMODE [CR]
Read selected Fan mode
6.9. Other Status Read Command Table
Status read command
Item
CR_SIGNAL [CR]
Read the status if there is signal or no signal
CR_VMUTE [CR]
Read No Show setting status
CR_FREEZE [CR]
Read Freeze setting status
CR_PTIMER [CR]
Read P-Timer operational status
CR_TEMPWARN [CR]
Read if sensors are exceeding critical temperature or not
CR_TEMPFAIL [CR]
Read the temperature when sensors approached critical
temperature
7.
Error Code Table
Error Code
Content
?
When receives data that cannot be decoded.
Parameter determination error. (Digit number error, and
incorrect letter included)
000
Normal Reception. (Not error)
101
The function is not available in the selected Mode.
102
Selected the value is out of range. (Selected value will not be
reflected)
103
Command mismatched to the Hardware. (Command for
unpopulated option function)
201
When sending command, the increment is maximum value or
the decrement is minimum value.
301
Processing image capture.
Re-try it again later.
302
Processing Auto setup, not executable.
Re-try it again later.
303
Processing Memory Card Viewer.
Re-try it again later.
402
Processing PIN Code, not executable.
Re-try it again later.
Note) this error code for Expand Command, not applicable for Basic Command.