Canon LV-5220 Serial Functional Specification - Page 25

CF_REAR Command, 11.6. CF_RCODE Command, 11.7. CF_LANG Command, 11.8. CF_ON-STA Command

Page 25 highlights

Expand Serial Command Functional Specification Page 24 of 41 8.11.5. CF_REAR Command Command "CF_REAR_%1" [CR] %1 "ON Select Rear "OFF" --------- Cancel Rear Details Set / Cancel Rear. (Only valid when it is in the usual Power On status) When Rear is On, it will be a mirror-reversed image. This setting status is stored in EEPROM, hold even if AC Power turning Off and On. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.6. CF_RCODE Command Command "CF_RCODE_%1" [CR] "001 Select Code1 "002 Select Code2 "003 Select Code3 %1 "004 Select Code4 "005 Select Code5 "006 Select Code6 "007 Select Code7 "008 Select Code8 Details Select Remote Control Code. (Only valid when it is in the usual Power On status) This setting status is stored in EEPROM, hold even if AC Power turning Off and On. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.7. CF_LANG Command Command "CF_LANG_%1" [CR] "ENG Select English "DEU Select German "FRA Select French "ITA Select Italy "ESP Select Spanish %1 "POR Select Portuguese "NED Select Dutch "SVE Select Swedish "RUS Select Russian "CHI Select Chinese "KOR Select Korean "JPN Select Japanese Details Set OSD Language. (Only valid when it is in the usual Power On status) This setting status is stored in EEPROM, hold even if AC Power turning Off and On. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.8. CF_ON-STA Command Command ""CF_ON-STA_%1" [CR] %1 "ON" -------- Select Power On Start "OFF" ------- Cancel Power On Start Details Set / Cancel Power ON Start. (Only valid when it is in the usual Power On status) This setting status is stored in EEPROM, hold even if AC Power turning Off and On. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Expand Serial Command Functional Specification
Page 24 of 41
8.11.5. CF_REAR Command
Command
²CF_REAR_%1± [CR]
%1
²ON± ---------- Select Rear
²OFF± --------- Cancel Rear
Details
Set / Cancel Rear. (Only valid when it is in the usual Power On status)
When Rear is On, it will be a mirror-reversed image.
This setting status is
stored in EEPROM, hold even if AC Power turning Off and On.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.11.6. CF_RCODE Command
Command
²CF_RCODE_%1± [CR]
%1
²001± ---------- Select Code1
²002± ---------- Select Code2
²003± ---------- Select Code3
²004± ---------- Select Code4
²005± ---------- Select Code5
²006± ---------- Select Code6
²007± ---------- Select Code7
²008± ---------- Select Code8
Details
Select Remote Control Code. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.11.7. CF_LANG Command
Command
²CF_LANG_%1± [CR]
%1
²ENG± ---------- Select English
²DEU± ---------- Select German
²FRA± ---------- Select French
²ITA± ------------ Select Italy
²ESP± ----------- Select Spanish
²POR± ---------- Select Portuguese
²NED± ---------- Select Dutch
²SVE± ---------- Select Swedish
²RUS± ---------- Select Russian
²CHI± ----------- Select Chinese
²KOR± ---------- Select Korean
²JPN± ---------- Select Japanese
Details
Set OSD Language. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.11.8. CF_ON-STA Command
Command
²±CF_ON-STA_%1± [CR]
%1
²ON± -------- Select Power On Start
²OFF± ------- Cancel Power On Start
Details
Set / Cancel Power ON Start. (Only valid when it is in the usual Power On
status)
This setting status is stored in EEPROM, hold even if AC Power
turning Off and On.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]