Canon LV-5220 Serial Functional Specification - Page 14

CF_SHARP Command, 4.6. CF_GAMMA Command, 4.7. CF_WBAL- Command, 4.8. CF_COLTEMP Command

Page 14 highlights

Expand Serial Command Functional Specification Page 13 of 41 8.4.5. CF_SHARP Command Command "CF_SHARP_%1" [CR] "000 - 015 Directly select the Sharpness setting value %1 "UP Sharpness setting value +1 "DN Sharpness setting value -1 Details Set the user control Sharpness value. The value set by the command will not be saved to the Projector. Therefore, when AC Power Off the Projector, the value will return to the original setting. (For Standby mode, this value stays) Only valid when it is in the usual Power On state. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.4.6. CF_GAMMA Command Command "CF_GAMMA_%1" [CR] "000 - 015 Directly select the Gamma setting value %1 "UP Gamma setting value +1 "DN Gamma setting value -1 Details Set the user control Gamma value. The value set by the command will not be saved to the Projector. Therefore, when AC Power Off the Projector, the value will return to the original setting. (For Standby mode, this value stays) Only valid when it is in the usual Power On state. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.4.7. CF_WBAL- Command Command "CF_WBAL-%1_%2" [CR] "R Red %1 "G Green "B Blue "000 - 063" ------- Directly select color value by White Balance %1 determination %2 "UP Color value for White Balance %1 determination +1 "DN Color value for White Balance %1 determination -1 Details Set the user control value by White Balance %1 determination. The value set by the command will not be saved to the Projector. Therefore, when AC Power Off the Projector, the value will return to the original setting. (For Standby mode, this value stays) Only valid when it is in the usual Power On state. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.4.8. CF_COLTEMP Command Command "CF_COLTEMP_%1" [CR] "000 Xlow %1 "001 Low "002 Mid "003 High Details Set the Color Temp. The value set by the command will not be saved to the Projector. Therefore, when AC Power Off the Projector, the value will return to the original setting. (For Standby mode, this value stays) Only valid when it is in the usual Power On state. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Expand Serial Command Functional Specification
Page 13 of 41
8.4.5. CF_SHARP Command
Command
²CF_SHARP_%1± [CR]
%1
²000 ´ 015± ------------ Directly select the Sharpness setting value
²UP± --------------------- Sharpness setting value +1
²DN± --------------------- Sharpness setting value -1
Details
Set the user control Sharpness value.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.4.6. CF_GAMMA Command
Command
²CF_GAMMA_%1± [CR]
%1
²000 ´ 015± ------------ Directly select the Gamma setting value
²UP± --------------------- Gamma setting value +1
²DN± --------------------- Gamma setting value -1
Details
Set the user control Gamma value.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.4.7. CF_WBAL- Command
Command
²CF_WBAL-%1_%2± [CR]
%1
²R± -------------------- Red
²G± -------------------- Green
²B± -------------------- Blue
%2
²000 ´ 063± ------- Directly select color value by White Balance %1 determination
²UP± ---------------- Color value for White Balance %1 determination +1
²DN± ---------------- Color value for White Balance %1 determination -1
Details
Set the user control value by White Balance %1 determination.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]
8.4.8. CF_COLTEMP Command
Command
²CF_COLTEMP_%1± [CR]
%1
²000± ----------- Xlow
²001± ----------- Low
²002± ----------- Mid
²003± ----------- High
Details
Set the Color Temp.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable
²000± [CR]
Response
Unacceptable
²Error Code± [CR]