C Blow off adhering substances using a blower, etc., or remove them by lightly wiping with a cotton swab, etc. Paper sensor D Load paper. E Close the Paper Cover. F Perform a test print to check that the printer is functioning properly. Platen Roller If foreign substances such as paper chips adhere to the Platen Roller, paper feed or print quality problems may occur. If they adhere to the Platen Roller, follow the steps below to clean it. IMPORTANT • Do not wipe off the yellow grease applied to the platen gear. Doing so may shorten its life. • Do not use solvents, etc. A Push the Cover Open Lever down to open the Paper Cover. B Lightly wipe the platen surface with a soft, dry cloth to remove the stains. Platen Roller C Close the Paper Cover. D Perform a test print to check that the printer is functioning properly. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

23
C
Blow off adhering substances using a blower, etc., or
remove them by lightly wiping with a cotton swab, etc.
D
Load paper.
E
Close the Paper Cover.
F
Perform a test print to check that the printer is functioning
properly.
Platen Roller
If foreign substances such as paper chips adhere to the Platen Roller,
paper feed or print quality problems may occur. If they adhere to the
Platen Roller, follow the steps below to clean it.
IMPORTANT
Do not wipe off the yellow grease applied to the platen gear. Doing so
may shorten its life.
Do not use solvents, etc.
A
Push the Cover Open Lever down to open the Paper
Cover.
B
Lightly wipe the platen surface with a soft, dry cloth to
remove the stains.
C
Close the Paper Cover.
D
Perform a test print to check that the printer is functioning
properly.
Paper sensor