Canon imageFORMULA CR-190i imageFORMULA CR-135i / CR-190i Instructions Manual - Page 53

Replacing the Rollers, Remove the Roller Cover.

Page 53 highlights

Replacing the Rollers When rollers are worn, paper jams and double feeds tend to occur. You can replace the rollers (Pickup Roller, Feed Roller, and Separation Roller) according to the following procedure. The exchange roller kit is not included with the scanner. Purchase an exchange roller kit separately, as shown below. Compatible exchange roller kit: 4623B001 A Remove the Top Cover. C Open the Feed Supporter to the left. B Remove the Roller Cover. Feed Supporter D Pinch the Separation Roller at the rim and the fixing lever, and then remove it with pressing the Separation OFF Mode Button. Fixing Lever 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

53
Replacing the Rollers
When rollers are worn, paper jams and double feeds tend to occur. You
can replace the rollers (Pickup Roller, Feed Roller, and Separation
Roller) according to the following procedure.
The exchange roller kit is not included with the scanner. Purchase an
exchange roller kit separately, as shown below.
Compatible exchange roller kit: 4623B001
A
Remove the Top Cover.
B
Remove the Roller Cover.
C
Open the Feed Supporter to the left.
D
Pinch the Separation Roller at the rim and the fixing lever, and
then remove it with pressing the Separation OFF Mode
Button.
Feed Supporter
Fixing Lever