Canon imageFORMULA CR-190i imageFORMULA CR-135i / CR-190i Instructions Manual - Page 56
Adjusting the Separation Roller Gap
View all Canon imageFORMULA CR-190i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
L Carefully replace the Top Cover. Adjusting the Separation Roller Gap If double feed should occur too often, adjust the Separation Roller gap according to the following procedure. A Slide the Adjustment Dial Cover to the left. M Adjust the Adjustment Dial to 5. For more information, see "Adjusting the Separation Roller Gap," on p. 56. Adjustment Dial Turn the dial to the left to widen the gap, and turn it to the right to narrow the gap. B Adjust the Adjustment Dial. Turn the Adjustment Dial to the right 3 clicks. If documents are not fed after the above operation, turn the Adjustment Dial back to the left 1 click. C Slide the Adjustment Dial Cover to the right. CAUTION Do not use the Adjustment Dial any other time except when adjusting the Separation Roller gap. Turning the Adjustment Dial too much may damage the scanner. 56