Chamberlain RJO20 RJO20 Owner s Manual - English - Page 14

Attach the Cable Tension Monitor, 8) Install the Door Control (myQ® Control Panel

Page 14 highlights

Screw #6 (2) Lag Screw 5/16"-9x2" Screw 1/4-20 (2) #8 Hex Head Screw (2) Installation (continued) 7 Attach the Cable Tension Monitor 1. Mark and drill 3/16 inch pilot holes for screws. If the cable tension monitor cannot be mounted into wood, it can be mounted into 1/2 inch (1 cm) or greater drywall using the drywall anchors (2) and the #8 screws (2) provided in the hardware bag.
 2. Attach the cable tension monitor to the wall using the hardware provided. Check that the roller is on top of the cable. 
 3. Run wire to garage door opener. Securely affix wire to wall and ceiling. Secure any additional wire away from the moving parts of the door. 4. Connect wire to the green quick-connect terminals on the garage door opener. NOTE: Cable must have tension through entire door travel. Check there is no slack in cable on opposite side of garage door during normal operation. If slack occurs during door travel, contact a trained door systems technician . Wall Anchor (2) YOU WILL NEED Screw 14-10x2" (2) Drywall Anchor (screw-in) (2) Screws #8-32x1" (2) #8 Hex Head Screw (2) Staples Screw #6 (2) Lag Screw 5/16"-9x2" Staples Screw 1/4-20 (2) Wall Anchor (2) Shim or add wood block if needed. The cable tension monitor MUST be flush with the mounting surface. The cable tension monitor roller must be free from obstructions. Wall Drum Wall Anchor (2) Staples Wall Anchor (2) Cable Tension Monitor Header Cable Tension Monitor Roller To insert or release wire, push in tab with screwdriver tip Cable WHT/ GRN Garage door opener Staples 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

14
Attach the Cable Tension Monitor
7
Drum
Header
Cable
Wall
Cable Tension
Monitor
Cable Tension
Monitor Roller
To insert or
release wire,
push in tab with
screwdriver tip
WHT/
GRN
YOU WILL NEED
Wall Anchor (2)
Screws
#8-32x1" (2)
Drywall Anchor
(screw-in) (2)
Screw
14-10x2" (2)
Installation
(continued)
1.
Mark and drill 3/16 inch pilot holes for screws. If the cable tension monitor
cannot be mounted into wood, it can be mounted into 1/2 inch (1 cm)
or greater drywall using the drywall anchors (2) and the #8 screws (2)
provided in the hardware bag.
2.
Attach the cable tension monitor to the wall using the hardware provided.
Check that the roller is on top of the cable.
3.
Run wire to garage door opener. Securely affix wire to wall and ceiling.
Secure any additional wire away from the moving parts of the door.
4.
Connect wire to the green quick-connect terminals on the garage door
opener.
NOTE:
Cable must have tension through entire door travel. Check there is no
slack in cable on opposite side of garage door during normal operation. If
slack occurs during door travel, contact a trained door systems technician .
Shim or add wood
block if needed.
The cable tension
monitor MUST
be flush with the
mounting surface.
The cable tension
monitor roller
must be free from