Cisco WS-X4624-SFP-E Hardware Maintenance Manual - Page 112
Side view, Top view, Front of the chassis, If you have completed all memory upgrade procedures
UPC - 882658134944
View all Cisco WS-X4624-SFP-E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
Memory Replacement Procedures Figure 5-12 Inserting Flash-Memory SIMMs Top view Front of the chassis 1. Insert the SIMM into the socket at an angle 45° from vertical. 2. Push the SIMM down and back. 3. The socket guide posts insert through the SIMM holes (on both sides). 4. The locking spring will clip the front side of the SIMM when it is fully installed (on both sides). Polarization notch Side view 1. Insert the SIMM into the socket at an angle 45° from vertical. 3. The socket guide posts insert through the SIMM holes (on both sides). 4. The locking spring will clip the front side of the SIMM when it is fully installed (on both sides). 2. Push the SIMM down and back. H2474 Caution You will feel some resistance, but do not use excessive force on the SIMM and do not touch the surface components to avoid damaging them. Step 4 Check the alignment of each SIMM to make sure that it is straight and that the alignment holes are lined up with the plastic socket guides. If you have completed all memory upgrade procedures, proceed to the section "Replacing Network Processor Modules" later in this chapter. 5-18 Cisco 4000 Series Hardware Installation and Maintenance