Your Detector Settings What to Remember While Using IntelliMute IntelliMute works with both City and Auto Mute modes. Whenever your engine revs are below the activation point, the dot next to the large character on the right side of the display will remain lit. Above the activation point, the dot will blink twice every two seconds. Below Activation Point Above Activation Point X K Ka V S c X K Ka V S c If, for any reason, the unit stops sensing your engine's revs, IntelliMute will indicate an error and automatically turn Off. The rev point you set will be stored in the unit's memory when power is turned Off and recalled each time the power is turned On. NOTE The rev point must be reset if you use your detector in a different vehicle. NOTE When initially choosing your IntelliMute activation point, a setting of approximately 300 to 600 RPMs above idle is recommended. You can reset the activation point at any time to fit your individual preferences and driving style. Setting the IntelliMute Activation Point Your detector must be installed in your vehicle. CAUTION Do not attempt to set the rev point while driving. Your vehicle should be parked and idling. IntelliMute must be turned on before setting the activation point. You will hear a series of beeps as you follow the steps on the next page. 10 English Your Detector Settings To Set the IntelliMute Activation Point Press and hold the IntelliMute button for two seconds. Tone Two beeps Rev your engine to None the level you wish to set (recommend slightly above idle) and hold revs steady for two seconds. At the desired rev level, press and release the IntelliMute button. Three beeps IntelliMute Button Press and release Visual Display None Three bars will flash in succession 1 2 3 All three bars flash three times 1 2 3 NOTE If the unit is unable to sense usable pulses within three seconds or if you do not set a rev point within 20 seconds of beginning these steps, IntelliMute will indicate an error and automatically turn Off. Tone Four beeps Visual Display E appears E X K Ka V S Nothing Comes Close to a Cobra® 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Settings
Your Detector
Nothing
Comes Close to a Cobra
®
11
Settings
Your Detector
English
What to Remember While Using IntelliMute
IntelliMute
works with both City and Auto Mute modes.
Whenever your engine revs are below the activation point, the dot next
to the large character on the right side of the display will remain lit.
Above the activation point, the dot will blink twice every two seconds.
If, for any reason, the unit stops sensing your engine’s revs,
IntelliMute will indicate an error and automatically turn Off.
The rev point you set will be stored in the unit’s memory when
power is turned Off and recalled each time the power is turned On.
NOTE
The rev point must be reset if you use your detector in a different vehicle.
NOTE
When initially choosing your IntelliMute activation point, a setting
of approximately 300 to 600 RPMs above idle is recommended.
You can reset the activation point at any time to fit your individual
preferences and driving style.
Setting the IntelliMute Activation Point
Your detector must be installed in your vehicle.
CAUTION
Do not attempt to set the rev point while driving.
Your vehicle should be parked and idling.
IntelliMute must be turned on before setting the activation point. You will
hear a series of beeps as you follow the steps on the next page.
10
Below Activation Point
X K Ka
V
S
c
Above Activation Point
X K Ka
V
S
c
To Set the IntelliMute Activation Point
Press and hold
the
IntelliMute
button for two
seconds.
Tone
Visual Display
Two beeps
None
Rev your engine to
the level you wish
to set (recommend
slightly above idle)
and hold revs steady
for two seconds.
None
Three bars will
flash in succession
At the desired
rev level, press
and release the
IntelliMute
button.
Three beeps
All three bars flash
three times
Tone
Visual Display
Four beeps
E
appears
X K Ka V S
E
1
2
3
1
2
3
NOTE
If the unit is unable to sense usable pulses within
three seconds or if you do not set a rev point within
20 seconds of beginning these steps, IntelliMute will
indicate an error and automatically turn Off.