Compaq DL580R01 Service Guide - Page 106
Message, Description, Recommended Action, Do not, Restart the system. Run the Array Configuration
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Diagnostics and Troubleshooting 3-37 Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Controller firmware Controller firmware is below the needs upgrading latest recommended version. Run Options ROMPaq Utility to upgrade the controller to the latest firmware revision. Controller is located in special "video" slot Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly. Install the controller in a different slot, and run the server setup utility to configure nonvolatile RAM. Then run Array Configuration Utility to configure the controller. Controller is not configured Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. ADU examines each physical drive and looks for drives that have been moved to a different drive bay. Look for messages indicating which drives have been moved. If none display and drive swapping did not occur, run the Array Configuration Utility to configure the controller and server setup utility to configure nonvolatile RAM. Do not run either utility if you believe drive swapping has occurred. Controller reported POST error Error Code: X The controller returned an error from its internal Power-On Self-Test (POST). Replace the controller. Controller restarted with a signature of zero ADU did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Run the server setup utility to configure the controller and nonvolatile RAM. Disable command issued The issuing of the Accelerator Disable command has disabled posted-writes. This occurred because of an operating system device driver. Restart the system. Run the Array Configuration Utility to reinitialize the array accelerator board. Drive (bay) X firmware needs upgrading Firmware on this physical drive is below the latest recommended version. Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision. Drive (bay) X has insufficient capacity for its configuration Drive has insufficient capacity to be Replace this drive with a larger capacity drive. used in this logical drive configuration. Drive (bay) X has invalid M&P stamp Physical drive has invalid monitor and performance data. Run the server setup utility to properly initialize this drive. Drive (bay) X has loose cable The array controller could not communicate with this drive at power up. This drive has not previously failed. Check all cable connections first. The cables could be bad, loose, or disconnected. Power up the system and attempt to reconnect data/power cable to the drive. If this does not work, replace the cable. If it is still unsuccessful, the drive may need to be replaced. Drive (bay) X is a replacement drive This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume. If the replacement was intentional, allow the drive to rebuild. continued