Drive Monitoring is
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
3-38 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Drive (bay) X is a replacement drive marked OK This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure. For example, a drive has previously failed, then starts working again when ADU is run. Replace the drive. Drive (bay) X is failed. The indicated physical drive has failed. Replace the drive. Drive (bay) X is undergoing drive recovery This drive is being rebuilt from the Normal operations should occur. corresponding mirror or parity data. Drive (bay) X needs The 210-MB hard drive has replacing firmware version 2.30 or 2.31. Replace the drive. Drive (bay) X upload code not readable An error occurred while ADU was trying to read the upload code information from this drive. If there were multiple errors, the drive may need to be replaced. Drive (bay) X was inadvertently replaced The physical drive was incorrectly replaced after another drive failed. 1. Replace the drive that was incorrectly replaced. 2. Replace the original drive that failed. Do not run the server setup utility and try to reconfigure. Drive Monitoring features are unobtainable ADU is unable to receive monitor and performance data due to fatal command problem (such as drive time-out), or unable to receive data due to these features not being supported on the controller. Check for other errors such as time-outs. If no other errors occur, upgrade the firmware to a version that supports the monitor and performance. Drive Monitoring is NOT enabled for SCSI Port X Drive ID Y The monitor and performance features have not been enabled on this drive. Run the server setup utility to initialize the monitor and performance features. Drive time-out ADU issued a command to a occurred on physical physical drive and the command drive bay X was never acknowledged. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Drive X indicates position Y Message indicates a designated physical drive, which shows it to be scrambled or in a drive bay other than the one for which it was originally configured. Examine the graphical drive representation on ADU to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the ADU instructions. continued