Danby DPAC9009 Use and Care Manual - Page 6

Installation

Page 6 highlights

INSTALLATION INSTALLATION ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing. Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2 pcs)... from 17 7/10" (45cm) up to 53 1/6" (135cm) Flexible Exhaust Hose (11cm) & Exhaust nozzle connector (2pcs)...from 15 3/4" (40cm) up to 51 1/5" (130cm) Ajustabl1e window door slider kit (3 pcs)..... from 28 /3"(72cm) up to 80" (203cm) Fixture..... (2 pcs) Screws......(12 pcs) Fig. 1 INSTALLATION ACCESSORIES Exhaust Nozzle Flexible Exhaust Hose Connector Fixture NOTE: The exhaust/window kit must be installed at all times when the unit is operating under AIR CONDITIONING mode. There should be at least 11.8" (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface. The unit does not have to be vented outside during Dehumidifying or Fan Only mode operation. Instructions for Assembling the Window Adapter Kit- Fig. 2 Screws Fig. 2 Adjustable Window Slider Kit: 28 1/3" (72cm)- 80" (203cm) Back of Window Pane 1) Insert tube adapters through the back of the window panel. 2) Secure each tube adapter with four screws through the front of the window panel. 3) Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place. Tube Adapters WINDOW KIT Air Conditioning Mode ONLY Your window kit has been designed to fit most standard "vertical"/"horizontal" windows up to a maximum height of 80" (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together. 1) Select a suitable location, making sure you have access to an electrical outlet. 2) Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the exhaust opening and twist to lock into position. 3) Install the adjustable Window Slider Kit as required (see Fig. 3a & 3b). 4) Install the opposite end of the flexible exhaust hose into the window exhaust adapter. 5) Install the window exhaust adapter into the opening in the slider section, making sure the window slider sections are secure. 6) Plug the unit into a 115V/60Hz grounded electrical outlet. Fig. 3a Horizontal Window Vertical Window Fig. 3b Window Slider Kit: Min.: 28 1/3" (72cm) Max.: 80" (203cm) Window Slider Kit: Min.: 28 1/3" (67.5cm) Max.: 80" (203cm) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

INSTALLATION
WINDOW KIT
Air Conditioning Mode ONLY
Your window kit has been designed to fit most standard “vertical”/”horizontal” windows up to
a maximum height of 80” (203cm). For vertical window applications, multi lock positions are
provided on the edge of each slider section to secure each sliding section together.
1)
Select a suitable location, making sure you have access to an electrical outlet.
2)
Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the
exhaust opening and twist to lock into position.
3)
Install the adjustable Window Slider Kit as required (see Fig. 3a & 3b).
4)
Install the opposite end of the flexible exhaust hose into the window exhaust adapter.
5)
Install the window exhaust adapter into the opening in the slider section, making sure
the window slider sections are secure.
6)
Plug the unit into a 115V/60Hz grounded electrical outlet.
Window Slider Kit:
Min.: 28
1
/
3
(67.5cm)
Max.: 80” (203cm)
Window Slider Kit:
Min.: 28
1
/
3
(72cm)
Max.: 80” (203cm)
5
Horizontal Window
Vertical
Window
Fig. 1
INSTALLATION ACCESSORIES
There should be at least 11.8” (30cm) clearance
between the unit and any other objects or
building structures, and should be installed on a
level surface. The unit does not have to be
vented outside during Dehumidifying or Fan
Only mode operation.
Flexible Exhaust Hose
Exhaust Nozzle
Connector
Fixture
Adjustable Window Slider Kit:
28 1/3” (72cm)- 80” (203cm)
INSTALLATION
Flexible Exhaust Hose
(13cm) &
Exhaust
nozzle connector
(2 pcs)... from 17
7
/
10
” (45cm)
up to 53
1
/
6
” (135cm)
Flexible Exhaust Hose
(11cm) &
Exhaust
nozzle connector
(2pcs)...from 15
3
/
4
” (40cm) up
to 51
1
/
5
” (130cm)
Ajustable window door slider kit
(3 pcs)
.....
from 28
1
/3”(72cm) up to 80” (203cm)
Fixture
.....
(2 pcs)
Screws
......
(12 pcs)
NOTE:
The exhaust/window kit must be installed
at all times when the unit is operating under AIR
CONDITIONING mode.
Screws
ELECTRIC SHOCK HAZARD:
To avoid the possibility of personal
injury, disconnect power to the unit before installing or servicing.
Back of Window Pane
Tube Adapters
Fig. 2
Instructions for Assembling the Window
Adapter Kit- Fig. 2
1)
Insert tube adapters through the back of the
window panel.
2)
Secure each tube adapter with four screws
through the front of the window panel.
3)
Insert window panel extensions into window
panel. Lightly tighten the screws in the window
panel to hold the extensions in place.
Fig. 3a