Dell External OEMR XL R610 Technical Guide - Page 10

Feature, NIC/LOM, Power Supplies

Page 10 highlights

Dell Feature RAID NIC/LOM USB Power Supplies Fans R510 SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 PERC S100: 0, 1, 5, 10 PERC S300: 0, 1, 5, 10 Broadcom® BCM5716 2 x iSCSI TOE Optional: various NICs available 2 front, 2 back, 2 internal Four-drive chassis: non-redundant, 480W Eight-drive and twelvedrive chassis: hot-plug redundant 750W Four-drive chassis: four non-redundant, non-hotpluggable fans Eight-drive chassis: five non-redundant, non-hotpluggable fans Twelve-drive chassis: five redundant, non-hotpluggable, dual-rotor fans R610 SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 Broadcom® BCM5709C 4 x iSCSI TOE Optional: various NICs available 2 front, 2 back, 1 internal Two redundant hot-plug high efficiency 502W or two redundant hot-plug high output 717W Six dual-rotor fans (dual processor configuration) or five dual-rotor fans (single processor configuration) R710 SAS 6/iR and PERC H200: RAID 0, 1 PERC 6/i and PERC H700: RAID 0, 1, 5, 6, 10, 50, 60 Broadcom® BCM5709C 4 x iSCSI TOE Optional: various NICs available 2 front, 2 back, 1 internal Two redundant hot-plug high efficiency 570W or two redundant hot-plug high output 870W Five hot-plug fans (default processor configuration) or four hot-plug fans (single processor configuration) PowerEdge R610 Technical Guide 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Dell
PowerEdge R610 Technical Guide
10
Feature
R510
R610
R710
RAID
SAS 6/iR and PERC H200:
RAID 0, 1
PERC 6/i and PERC H700:
RAID 0, 1, 5, 6, 10, 50,
60
PERC S100: 0, 1, 5, 10
PERC S300: 0, 1, 5, 10
SAS 6/iR and PERC H200:
RAID 0, 1
PERC 6/i and PERC H700:
RAID 0, 1, 5, 6, 10, 50,
60
SAS 6/iR and PERC H200:
RAID 0, 1
PERC 6/i and PERC H700:
RAID 0, 1, 5, 6, 10, 50,
60
NIC/LOM
Broadcom
®
BCM5716
2 x iSCSI TOE
Optional: various NICs
available
Broadcom
®
BCM5709C
4 x iSCSI TOE
Optional: various NICs
available
Broadcom
®
BCM5709C
4 x iSCSI TOE
Optional: various NICs
available
USB
2 front, 2 back,
2 internal
2 front, 2 back,
1 internal
2 front, 2 back,
1 internal
Power Supplies
Four-drive chassis:
non-redundant, 480W
Eight-drive and twelve-
drive chassis: hot-plug
redundant 750W
Two redundant hot-plug
high efficiency 502W or
two redundant hot-plug
high output 717W
Two redundant hot-plug
high efficiency 570W or
two redundant hot-plug
high output 870W
Fans
Four-drive chassis: four
non-redundant, non-hot-
pluggable fans
Eight-drive chassis: five
non-redundant, non-hot-
pluggable fans
Twelve-drive chassis:
five redundant, non-hot-
pluggable, dual-rotor
fans
Six dual-rotor fans (dual
processor configuration)
or
five dual-rotor fans
(single processor
configuration)
Five hot-plug fans
(default processor
configuration) or
four hot-plug fans (single
processor configuration)