Dell External OEMR XL R610 Technical Guide - Page 23
Power Consumption Testing
View all Dell External OEMR XL R610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Dell Maximum Shock Storage Altitude Operating Storage Half sine shock on all six sides of 71G 5% with a pulse duration of 2ms 10% Square wave shock on all six sides of 27G with velocity change @ 235 in/sec or greater -16 to 3048m (-50 to 10,000ft) Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550ft -16 to 10,600m (-50 to 35,000ft) 5.6 Power Consumption Testing Table 6. Power Consumption Testing Feature Dimensions Status Indicators Integrated Fans Fixed Input Plug Energy Smart Power Supply High Output Power Supply L-249 mm1 x W-65.5 mm x H-38.2 mm 1 x bi-color Light Emitting Diode None IEC-C14 AC Cord Rating 15 Amps @ 120 VAC, 10 Amps @ 240 VAC Input Voltage 90-264 VAC Auto-ranging Yes Line Frequency 47-63 Hertz Maximum Inrush Current 55 Amps per supply for 10 ms or less Hot-Swap Capability Yes Output Power 502 Watts 717 Watts Maximum Heat Dissipation 1712.9 BTU per hour 2446.5 BTU per hour Efficiency (20% - 100% Load) 86.5-90% @ 115 VAC 88-92% @ 230 VAC 85-88.5% @ 115 VAC 86.5-90.5% @ 230 VAC 1 Does not include the power supply handle or ejection tab PowerEdge R610 Technical Guide 23